WIRING
Note: This range hood must be properly grounded. The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes.
1.Remove the wiring box cover. Remove a knockout from the wiring box.
2.Secure the conduit to the wiring box through a conduit connector.
3.Make electrical connections. Connect white to white, black to black and green to green.
4.Replace wiring box cover and screws. Make sure that wires are not pinched between cover and box.
CONNECT DUCTWORK
1.Use screws (4.8x38mm) and wall anchors to secure flue mounting bracket to the ceiling or wall as shown.
2.Use 8" round metal duct to connect the duct collar on the hood to the ductwork above.
3.Use duct tape to make all joints secure and air tight.
4.Connect the upper flue to the bracket with screws provided (3.9x9.5mm).
5.Slide the lower flue downward, until it fits properly around hood.
6.Secure decorative flue to hood with screws provided (3.9x9.5mm).
FASTEN
FLUE TO
HOOD & FLUE
MOUNTING
BRACKET WITH
SCREWS
(3.9x9.5mm)
WIRING BOX
COVER
DUCT
COLLAR
FLUE |
| |
MOUNTING | FASTEN | |
BRACKET | ||
FLUE | ||
| ||
| MOUNTING | |
| BRACKET | |
| TO CEILING OR | |
| WALL WITH | |
| SCREWS | |
| (4.8x38mm) | |
|
|
DECORATIVE
FLUE
DUCT TAPE
8" ROUND
METAL DUCT
- 7 -