2. PREPARE THE INSTALLATION
Make sure that the following items are included:
-Range Hood
-Wood strip
-Installation Manual
-Transition (9” x 18” to 10” round)
-Box of Accessories including:
•Baffle filters (3 or 4 depending on range hood dimensions)
•Lights (120 V, 50 W, type GU10, shielded halogen lamps) (2 or 4 depending on range hood dimensions)
•Trim rings for lights (2 or 4 depending on range hood dimensions)
•Bag of parts including:
(3)waterproof wire connectors, (2) wire clamps, (8) #8 x 3⁄8” screws (not used), (8) #8 x 3⁄4” screws,
(4)
Parts sold separately:
-Interior blower P12D
-Ductwork, elbows, dampers, wall and roof caps. Refer to page 3 for a complete list of venting options and model numbers.
NOTE: During installation, protect countertop and/or cooktop.
3. INSTALL BACKSPLASH (OPTIONAL)
ABWPD Series
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able to install the backsplash, make sure there is at least 18’’ (457 mm) clearance between bottom of hood and range control panel or cooktop. (refer to instructions included with backsplash).
CAUTION
If this backsplash is installed in a saline environment (e.g. coast), rinse all surfaces once a week with clear water, (even if the hood is not used) and wipe dry completely.
4. INSTALL WOOD STRIP
Measure and mark a level line on wall above cooktop location for the wood mounting strip (see illustration on page 4).
Center the provided wood mounting strip over location. Secure strip to the wall studs or framing with provided
WOOD STRIP
(CENTERED HORIZONTALLY & SECURED
TO WALL STUDS OR FRAMING)
LEVEL LINE
(SEE PAGE 4
FOR DIMENSIONS)
HD0046
CAUTION
Due to the weight of this hood, ensure that the wood strip is attached to all of the available wall studs (2 studs minimum for the 36’’ hood, more as hood width increases); not into the drywall alone.
- 5 -