KVSP/TKVSP Owner’s Manual

SOUND

SOUND LEVEL 92 dB(a) at Operator Position

Sound tests were conducted in accordance with 2000/14/EEC, and were performed on 7-25-07 under the conditions listed below.

Sound power level listed is the highest value for any model covered in this manual. Please refer to serial plate on the unit for the sound power level for your model.

General Conditions:

Sunny

Temperature:

88oF (31.1oC)

Wind Speed:

2 mph (3.8 kmh)

Wind Direction:

South South East

Humidity:

44%

Barometric Pressure:

30.07”Hg (764 mm Hg)

VIBRATION DATA

VIBRATION LEVEL 0.34g (3.29m/s2)

Vibration levels at the operator’s handles were measured in the vertical, lateral and longitudinal directions using calibrated vibration test equipment. Tests were performed on 12-19-2007 under the conditions listed below.

General Conditions:

Sunny

Temperature:

50oF (10oC)

Wind Speed:

4 mph (6.4kph)

Wind Direction:

South Southeast

Humidity:

68%

Barometric Pressure:

30 Hg (101.6kpa)

INTENDED USE

INTENDED USE: This machine is designed for vacuuming leaves, grass clippings and other types of organic litter.

Debris mixed with cans, bottles and small amounts of sand can be vacuumed; however, it is not this machine's primary purpose. Vacuuming cans, bottles and sand will affect the longevity of your machine.

Do not operate if excessive vibration occurs. If excessive vibration occurs, shut engine off immediately and check for damaged or worn impeller, loose impeller bolt, loose impeller key, loose engine or lodged foreign objects. Note: See parts list for proper impeller bolt torque specifications. (See trouble shooting section on page 12).

Part No 891058

6

Form No F042508A

Page 6
Image 6
Billy Goat F042508A owner manual Sound, Vibration Data, Intended USE