TROUBLESHOOTING

Problem Solution

Routine Maintenance

The Bionaire® Air Exchange System is easy to use and maintain.

8. If it is a black washable filter, clean it as described in step 6.

Service Instructions

If you need to exchange the unit within 30 days of purchase, please

System will not operate

Confirm that the unit is plugged into a working electrical outlet.

Confirm that the Damper Switch (1) is in the ON position.

Check to make sure the system is on by pressing the Mode Button (2).

Make sure that all bags have been removed from the filters.

It includes filters that remove dust from air that is circulated through the system. These filters will need to be cleaned or replaced with use. The Service Indicator bar graph on the display (6) shows when service is needed. The Service Indicator bar graph decreases - and when the bars disappear, the filters need to be cleaned. The aver- age duration between cleanings is about three months. WARNING: Do not attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. This unit contains no user serviceable parts. Only qualified personnel should perform servicing—other than what is described in this manual.

9. Remove the rubber Vacuum Plug from opening #5. See Figure 25.

10.Using a vacuum with a hose and a crevice tool, GENTLY vacuum the dust from the core by accessing openings #2 and

#5. See Figure 26. CAUTION: Avoid applying pressure or scraping the surface

return it in its original carton with the sales receipt to the store from which it was purchased.

If you need to return the unit beyond 30 days after you purchased it, review the warranty information provided with the unit and call 1-800-253-2764 for warranty service. You will be given a return authorization number and instructions returning the unit from the customer service representative.

WARRANTY

EverFreshTM

Air Exchange

System

MODEL BAP336

Decreased airflow

• It should be noted that the air entering

 

the room is designed to be at a low

 

flow rate to prevent drafts.

 

• Confirm that nothing is blocking the air

 

inlet and outlet.

 

• If “SERVICE” is displayed and the per-

 

formance bars are low, the filters need

 

to be cleaned. See Routine

 

Maintenance Instructions.

 

• Check the condition of the filters.

 

See Routine Maintenance Instructions.

Drafts around

• Check to make sure that the foam seal-

About the Filters

Figure 18

There are three black washable filters installed in the Air Exchange System. Each has a single tab that locks them into the unit. See Figure 18.

There is one two-tab filter installed in the Air Exchange System. This

will either be a black washable filter Figure 19 or a white disposable Electrostatic

filter. The Electrostatic filter removes smaller particles from the circulating air. See Figure 19.

of the core with the crevice tool as this may damage the core and decrease performance of the Air Exchange System.

11.

Replace the rubber Vacuum

 

 

 

Plug in opening #5. See Figure 25.

12.

After the filters are completely dry replace the three black filters

 

over openings #2, #3, #4.

13.

Insert a clean, dry black filter or a new white electrostatic filter

 

over opening #1.

14.

Clean the rear grill with warm soapy water. (Not dish washer

 

safe). Dry with a soft cloth.

15.

Remove dust from the front grill with a small soft brush or cloth.

The Manufacturer warrants to the first retail purchaser, for FIVE ( 5 ) YEARS from the date of original purchase, either to repair or replace at its option, without charge (parts and labor), any supplied or man- ufactured part of this Air Exchange System which, upon inspection by an authorized service center, proves to have failed in normal use due to defects in material or workmanship, or at its option, to replace the unit. Operation under conditions other than those rec- ommended or at voltages other than the voltage indicated on the unit, or any attempts by unauthorized personnel to service the unit or modify it, will render the guarantee void. The Manufacturer shall not be liable for any personal injury, property damage or any inci- dental or consequential damages of any kind (including water dam-

window

ing system is correctly installed.

 

• The leftover foam segments can be

 

used to seal any remaining openings.

PERFORMING MAINTENANCE

1.Confirm that the Service Indicator bars (6) no longer illuminate and the word "SERVICE" displays. This signals that maintenance is required.

2.Turn off and unplug the unit.

3.Remove the Air Exchange System from the Window Sealing Frame: See Figure 20.

Grasp each side of the Air Exchange System and gently pull it toward you.

Place the unit on a clean, level surface.

4.Remove the front grill. See Figure 21.

5.To remove the rear grill: See Figure 22.

Put the unit with the face down on the surface.

Place your thumb under the opening in the rear grill and pull up. One side of the grill will lift up and you will be able to slide the grill out.

6.Remove the black filters from openings #2, #3, and #4. Gently wash these filters with mild soapy water. Rinse in warm running water. Shake off excess water and allow to air dry completely. See Figure 23.

7.Remove the filter from opening #1. If it is a white electrostatic filter, dis- card it and replace with a fresh fil- ter. Call 1 (800) 253-2764 to order replacement filters. See Figure 24.

Figure 20

Figure 21

Figure 22

Figure 23

Opening # 3

Opening # 5

Opening

# 4

Opening # 2

Figure 24

16.

Wipe down the rest of the unit with a clean, damp cloth.

 

WARNING: DO NOT IMMERSE THE AIR EXCHANGE

 

SYSTEM IN WATER.

17.

Reinstall the rear grill:

 

 

See Figure 27.

Put the unit with the front grill face down on the surface.

Place the grill on the rear of the unit with the thumb opening toward the bottom (power cord side) of the unit.

Gently press down on the edges of the grill until all edges

are securely latched.

18. Put the unit on the table in the normal position and replace the front grill. See Figure 28.

19.Slide the Air Exchange Unit into the Window Sealing

Frame and push until it locks in place.

20.Insert the electrical plug into the outlet and turn the unit on.

21.Reset the service indicator by inserting the tip of a paper clip into the Service Reset Hole (5) and gently pressing the button inside the hole.

22.The Service Indicator bar graph should reappear.

Replacement Filters

Order these filters by calling 1 (800) 253-2764

Filter Part

Q u a n t i t y

Description

 

Number

Required

 

 

APF18

1 ea.

Electrostatic Filter, 2-Tab - Optional

 

 

 

 

APF19

3 ea.

Washable Foam Filter

1-Tab

APF20

1 ea.

Washable Foam Filter

2-Tab

 

 

 

 

age), resulting from defects, malfunctions, misuse, improper installa- tion or alteration of the product.

THE MANUFACTURER EXPRESSLY DISCLAIMS ALL RESPONSIBILITY FOR CONSEQUENTIAL DAMAGES OR INCIDENTAL LOSSES CAUSED BY USE OF THIS PRODUCT.

The provisions of this Warranty are in addition to, and not a modification of, or subtraction from the statutory warranties and other rights and remedies contained in any applicable legislation and to the extent that any such provision purports to disclaim, exclude or limit any such statutory warranties or other rights or remedies, such provisions shall be deemed to be amended to the extent necessary to comply therewith.

For Warranty Service, please call 1-800-253-2764 in North America.

KEEP THIS NUMBER FOR FUTURE REFERENCE.

A Bionaire® consumer service representative will help determine which is the best procedure for your Air Exchange System to be repaired.

If you have questions or comments, feel free to write us at:

Consumer Service Department

13120 Jurupa Avenue

Fontana, CA 92337

Bionaire®, the Bionaire logo® and EverFreshTM are trademarks of JCS/THG, LLC.

Bionaire®

JCS/THG, LLC

Consumer Service Department

13120 Jurupa Avenue

Fontana, CA 92337

BAP33605EM2/9100040002234

Printed In China

Read instructions before operating.

Retain for future reference.

Instruction Leaflet

INFO-LINE

If after having read this leaflet, you have any questions or comments on air cleaner, call 1-800-253-2764in North America.

Opening # 1 Service Instructions

Page 1
Image 1
Bionaire BAP336 warranty Instruction Leaflet, EverFreshTM Air Exchange System, Routine Maintenance, Service Instructions