IMPORTANT SAFEGUARDS
Figure 1
Window Sill
Insullation
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Figure 11

BAP33605EM2.qxd 10/14/05 9:27 AM Page 2

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFEGUARDS

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

Read all instructions before using the appliance.

To avoid fire or shock hazard, plug the product directly into a

 

120V AC electrical outlet.

Remove any plastic bags before use.

Keep the cord out of heavy traffic areas. To avoid fire hazard,

 

NEVER put the cord under rugs, near heat registers, radiators,

 

stoves, or heaters.

To protect against electrical hazards, DO NOT immerse in

 

water or other liquids. Do not use near water.

Close supervision is necessary when any appliance is used by

 

or near children, or disabled persons.

Avoid contact with moving parts.

Always unplug the product before moving it, opening the grill,

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

CONSUMER SAFETY INFORMATION

THIS PRODUCT IS EQUIPPED WITH A 3-PRONG PLUG. This product is for use on 120 volts.

The cord has a plug (A) as shown. Use an adapter (C) (not included) for connecting three-blade grounding -type plugs to two-slot recep- tacles (B). The green grounding lug extending from the adapter must be connected to a permanent ground

such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.

DO NOT DEFEAT THE SAFETY

PURPOSE OF THIS PLUG IN ANY

WAY.

CORD AND PLUG INSTALLATION SAFETY NSTRUCTIONS

Figure 2

A

GCONSUMER SAFETY INFORMATION

A.Air Exchange Unit

B.Window Sealing Frame

C.Left and Right Plastic Extender Panel (with window width indicators)

D.Foam Insulation Blocks

CORD AND PLUG INSTALLATION SAFETY NSTRUCTIONSB

F

GENERAL INFORMATION C, D

E1 UNPACKINGE2

E.Window Sill J hooks (two options for best window sill fit)

1.Standard Window J Hook – for use with most window types

2.Extended Window Sill J Hook – for use with Andersen® type windows.

F.Sash Insulation

G.Extra Foam

6.Next you must customize the Plastic Extender Panels so that the Window Sealing Frame will fit securely in your window. Each Plastic Extender Panel is divided into segments stamped with measurements between 26 to 38 inches. These measurements represent the total inside measurement, in inches, of various sized windows. See Figure 7.

CAUTION: Once you have removed segments from the Plastic Extender Panels, the frame will only fit in windows equal to or less than the width you have selected.

Figure 7

Back Side

Window

Width

Indicator

Plastic Extender SegmentsFront Side

11.Remove the excess foam segments at the seam. Save the extra segments. They can be used to fill any gaps in the window seal.

12.Repeat the process for the other Plastic Extender Panel. 13.Hold the Window Sealing Frame

so the rim-side of the assembly is facing outside and the locking clamp is on top. See Figure 11.

14.Insert the right side of the Window Sealing Frame into the window frame and into the win- dow track. See Figure 12.

15.Firmly push the left side of the Window Sealing Frame into the

window frame and into the win- dow track. See Figure 13. Then,

gently press the Window Sealing Frame down so that it is seated in the window.

16.Close the window. Make sure the bottom edge of the window

sash is resting on the foam strip, sealing any gaps around

Write room size here: ________________SQ. FT

If additional Plastic Extender Panels and Foam blocks are needed, contact Consumer Service 1- 800-253-2764.

OPERATION OF THE EVERFRESHTM AIR EXCHANGE SYSTEM INSTRUCTIONS

To turn on the system:

1.Plug the power cord into a wall outlet.

2.Turn the Damper Switch (1) to the the “ON” position.

3.Press the Mode Button (2).

Figure 17

Layout of controls and display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) Damper Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opens system to the out-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2) Mode Button

 

 

 

 

 

 

 

 

 

 

 

 

 

(3)Turns Heat

 

 

 

 

Turn motor on/off

 

 

 

 

 

 

 

 

 

 

 

 

 

Balance on/off

 

 

 

 

Select motor speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(6) Performance Bars

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(4) Display. Shows motor speed, number of air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exchanges/day, programmed room size, heat

 

 

 

 

 

(5) Service Reset

 

 

 

 

 

balance on/off, and service indicator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

changing the filters, cleaning, or whenever the product is not in

 

use. Be sure to pull by the plug and not the cord.

NEVER drop or insert any object into any openings other than

 

instructed in this manual.

DO NOT operate any appliance with a damaged cord or plug,

 

if motor fan fails to rotate, after the appliance malfunctions, or

 

if it has been dropped or damaged in any manner. Return

 

appliance to manufacturer for examination, electrical or

 

mechanical adjustment, or repair.

• Use appliance only for intended household use as described in

 

this manual. Any other use not recommended by the manufacturer

 

may cause fire, electric shock, or injury to persons. The use of

 

attachments not recommended or sold by JCS/THG,LLC may

 

cause hazards.

NEVER block the air openings, grills/outlets or place objects

 

that would cause blockage of the air intake/exhaust openings.

Keep unit away from heated surfaces and open flames.

DO NOT attempt to repair or adjust any electrical or mechani-

 

cal functions on this unit. Doing so will void the warranty on

 

serviceable parts. All servicing should be performed by

 

qualified personnel only.

WARNING: To reduce the risk of fire or electric shock, DO NOT

 

use this product with any solid-state speed control device.

Install horizontally only in a double hung window as described

 

in this manual.

All filter servicing should be performed from inside the room.

 

Outside filters should be serviced by first sliding the unit out of

 

the Window Sealing Frame and into the room.

• DO NOT use unit as a shelf or place anything on top of unit.

The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the product. Care must be taken to arrange the extension cord so that it will not drape on obstacles where it can be pulled on by children or accidentally tripped over.

Thank you for choosing The EverFresh™ Air Exchange System. To ensure the best performance from your new product, please read these instructions completely before beginning installation and operation.

GENERAL INFORMATION

The EverFresh™ Air Exchange System is designed to fit in double hung windows only.

The window opening can be between 26 inches and 38 inches wide.

You will need an electrical outlet within five (5) feet of the center of the window.

You will need a black marker, scissors, a Phillips head screwdriver, and a tape measure to install the unit.

UNPACKING

1. Carefully unpack the contents from the carton and remove the Air Exchange System from the

plastic bag.

2. Place the Air Exchange System

on a clean surface, with the front

grill facing down and slide the Window Sealing Frame off the

back of the unit. See Figure 1.

3. Remove the two Plastic Extender Panels from the plastic bags and

then remove the Foam Insulation Blocks from inside the Plastic Extender Panels.

4.Verify that you received all of the parts shown in Figure 2. If any parts are missing, please contact our consumer service depart- ment at 1-800-253-2764.

INSTALLATION

You must install the Window Sealing Frame into the track for your lower window sash before loading the Air Exchange System into the Window Sealing Frame.

1.Measure the frametrack for your lower window sash, at its widest point. See Figure 3.

Write your measurement here:____________

You may close the window temporarily.

2.If your window has a screen or storm window, measure the dis- tance between the front of the window (the side facing inside) to the screen or storm window. If that measurement is less than five (5) inches, you will need to remove the screen or storm win- dow before you can install the Window Sealing Frame.

3.Place the Window Sealing Frame on a flat surface, rim-side up, with the locking clamp away from you. See Figure 4.

4.Place the Plastic Extender Panel stamped LEFT, on the left side of the Window Sealing Frame and the Plastic Extender Panel stamped RIGHT on the right side. See Figure 5.

5.Slide the Plastic Extender Panels down into the guides on the sides of the Window Sealing Frame and press down gently until the Plastic Extender Panels click into place. See Figure 6.

Figure 3

Figure 4 Locking Clamp

Figure 5

 

Left Extender

Right Extender

Panel

Panel

Figure 6

7.Use the black marker to mark the number on each Plastic Extender Panel that is closest to (but not greater than), the measurement you recorded in Step 1. For example, if your win- dow is 33 inches wide, mark the number 32. See Figure 8.

8.Snap off each segment of the front of the Plastic Extender Panel

with a higher number than you

 

 

Figure 8

 

marked. If you marked 32 in

 

 

 

step 8, you only will remove the

 

 

segments for 38, 36 and 34 and

 

 

three segments from the back of

 

 

the Plastic Extender Panel. Use

 

 

a forward and backward motion

 

 

to remove the excess sections

 

 

 

 

along the scored indications.

 

 

Figure 9

 

See Figure 9. Remove the same

 

 

 

number of segments from the

 

 

back of the Plastic Extender

 

 

Panel.

 

 

9.Repeat this process on the other

 

 

Plastic Extender Panel.

 

 

10.Install the Foam Insulation

 

 

 

 

Blocks into the Plastic Extender

 

 

Figure 10A

 

Panels. Note that the Foam

 

 

 

Insulation Blocks are divided into

 

 

vertical segments of various

 

 

widths. The foam is installed

 

 

with these segments oriented

 

 

vertically. See Figure 10A. Insert

 

 

a Foam Insulation Block into the

 

 

 

 

right Plastic Extender Panel. For

 

 

proper fit, the foam should be

Figure 10B

 

only slightly wider than the

 

 

Plastic Extender Panel. If the

 

 

foam is the exact size, rotate the

 

 

foam block to utilize the half-size

 

 

foam block on the opposite

Small

 

side. Reinstall the foam into the

Block

Large Blocks

Plastic Extender Panel. See

 

 

 

 

Figure 10B.

 

 

the Window Sealing Frame.

17.Tighten the locking screw using a Phillips head screwdriver. Be careful to not over tighten. See Figure 14.

18.Install the appropriate window sill J- Hooks into the Window Sealing Frame. (See the parts list.) Slide the J-Hook until it is firmly seated against the mold- ing. See Figure 15.

NOTE: These hooks may not fit some older window moldings.

19.Install the Sash Insulation Strip as shown in Figure 16.

20.Before installing the Air Exchange Unit, verify that:

a)All foam strips are in place and that there are no visible gaps.

b) The window sash is firmly closed against the foam strip on top of the Window Sealing Frame.

c)The locking clamp tightly grips the window sash.

d)The foam blocks are tightly sealed against the window frame.

e)If used, the window sill J-Hooks are secured to the window sill.

f)Sash Insulation strip is in place.

g)Use the extra foam strips or segments to fill in any visible gaps. 21.Slide the Air Exchange Unit into the Window Sealing Frame and

push until it locks (clicks) into place.

22.For maximum efficiency, you will need to know the size of the room in square feet. (Measure room length and width in feet and multiply. Length X Width=Room Size in Sq. Ft.)

NOTE: When you use the unit for the first time, there may be a slight residual odor from the manufacturing process. This will disap- pear with use.

For best efficiency, we recommend that you program your system to the size of your room.

4.Refer the room measurement you made in step 22 of the Installation Instructions.

Your room is:

Small if it is 90 -159 sq. ft. Medium if it is 160-249 sq. ft Large if it is 250-399 sq. ft.

5.Press and hold the Mode button (2) and the Heat Balance but- ton (3) for three seconds, until the word small flashes.

6.Release the Mode button (2) and press the Heat Balance button

(3)until the desired room size is displayed.

The unit has three motor speeds plus OFF: Normal, Low, Turbo, OFF.

Press the mode button (2) repeatedly until the desired motor speed is displayed. The Air Exchange System is equipped with a Heat Balance setting. When this setting is on, the system equalizes the outside air it draws in to the air temperature of the room.

To Turn on the Heat Balance setting: Press the Heat Balance button (3) once.

Page 2
Image 2
Bionaire BAP336 warranty Important Safeguards, Consumer Safety Information, Cord And Plug Installation Safety Nstructions