BAP33605EM2.qxd 10/14/05 9:27 AM Page 2
PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
• | Read all instructions before using the appliance. |
• | To avoid fire or shock hazard, plug the product directly into a |
| 120V AC electrical outlet. |
• | Remove any plastic bags before use. |
• | Keep the cord out of heavy traffic areas. To avoid fire hazard, |
| NEVER put the cord under rugs, near heat registers, radiators, |
| stoves, or heaters. |
• | To protect against electrical hazards, DO NOT immerse in |
| water or other liquids. Do not use near water. |
• | Close supervision is necessary when any appliance is used by |
| or near children, or disabled persons. |
• | Avoid contact with moving parts. |
• | Always unplug the product before moving it, opening the grill, |
PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS
CONSUMER SAFETY INFORMATION
THIS PRODUCT IS EQUIPPED WITH A
The cord has a plug (A) as shown. Use an adapter (C) (not included) for connecting
such as a properly grounded outlet box. The adapter should not be used if a
DO NOT DEFEAT THE SAFETY
PURPOSE OF THIS PLUG IN ANY
WAY.
CORD AND PLUG INSTALLATION SAFETY NSTRUCTIONS
Figure 2 | A |
G
A.Air Exchange Unit
B.Window Sealing Frame
C.Left and Right Plastic Extender Panel (with window width indicators)
D.Foam Insulation Blocks
B
F
C, D
E1 E2
E.Window Sill J hooks (two options for best window sill fit)
1.Standard Window J Hook – for use with most window types
2.Extended Window Sill J Hook – for use with Andersen® type windows.
F.Sash Insulation
G.Extra Foam
6.Next you must customize the Plastic Extender Panels so that the Window Sealing Frame will fit securely in your window. Each Plastic Extender Panel is divided into segments stamped with measurements between 26 to 38 inches. These measurements represent the total inside measurement, in inches, of various sized windows. See Figure 7.
CAUTION: Once you have removed segments from the Plastic Extender Panels, the frame will only fit in windows equal to or less than the width you have selected.
Figure 7
Back Side
Window
Width
Indicator
Plastic Extender SegmentsFront Side
11.Remove the excess foam segments at the seam. Save the extra segments. They can be used to fill any gaps in the window seal.
12.Repeat the process for the other Plastic Extender Panel. 13.Hold the Window Sealing Frame
so the
14.Insert the right side of the Window Sealing Frame into the window frame and into the win- dow track. See Figure 12.
15.Firmly push the left side of the Window Sealing Frame into the
window frame and into the win- dow track. See Figure 13. Then,
gently press the Window Sealing Frame down so that it is seated in the window.
16.Close the window. Make sure the bottom edge of the window
sash is resting on the foam strip, sealing any gaps around
Write room size here: ________________SQ. FT
If additional Plastic Extender Panels and Foam blocks are needed, contact Consumer Service 1-
OPERATION OF THE EVERFRESHTM AIR EXCHANGE SYSTEM INSTRUCTIONS
To turn on the system:
1.Plug the power cord into a wall outlet.
2.Turn the Damper Switch (1) to the the “ON” position.
3.Press the Mode Button (2).
Figure 17 | Layout of controls and display |
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| (1) Damper Switch |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Opens system to the out- |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| side |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (2) Mode Button |
|
|
|
|
|
|
|
|
|
|
|
|
| (3)Turns Heat |
|
|
| ||
| Turn motor on/off |
|
|
|
|
|
|
|
|
|
|
|
|
| Balance on/off |
|
|
| ||
| Select motor speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (6) Performance Bars |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (4) Display. Shows motor speed, number of air |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| exchanges/day, programmed room size, heat |
|
|
|
|
| (5) Service Reset |
|
|
|
| |||||||||
| balance on/off, and service indicator. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| changing the filters, cleaning, or whenever the product is not in |
| use. Be sure to pull by the plug and not the cord. |
• | NEVER drop or insert any object into any openings other than |
| instructed in this manual. |
• | DO NOT operate any appliance with a damaged cord or plug, |
| if motor fan fails to rotate, after the appliance malfunctions, or |
| if it has been dropped or damaged in any manner. Return |
| appliance to manufacturer for examination, electrical or |
| mechanical adjustment, or repair. |
• Use appliance only for intended household use as described in | |
| this manual. Any other use not recommended by the manufacturer |
| may cause fire, electric shock, or injury to persons. The use of |
| attachments not recommended or sold by JCS/THG,LLC may |
| cause hazards. |
• | NEVER block the air openings, grills/outlets or place objects |
| that would cause blockage of the air intake/exhaust openings. |
• | Keep unit away from heated surfaces and open flames. |
• | DO NOT attempt to repair or adjust any electrical or mechani- |
| cal functions on this unit. Doing so will void the warranty on |
| serviceable parts. All servicing should be performed by |
| qualified personnel only. |
• | WARNING: To reduce the risk of fire or electric shock, DO NOT |
| use this product with any |
• | Install horizontally only in a double hung window as described |
| in this manual. |
• | All filter servicing should be performed from inside the room. |
| Outside filters should be serviced by first sliding the unit out of |
| the Window Sealing Frame and into the room. |
• DO NOT use unit as a shelf or place anything on top of unit. |
The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the product. Care must be taken to arrange the extension cord so that it will not drape on obstacles where it can be pulled on by children or accidentally tripped over.
Thank you for choosing The EverFresh™ Air Exchange System. To ensure the best performance from your new product, please read these instructions completely before beginning installation and operation.
GENERAL INFORMATION
•The EverFresh™ Air Exchange System is designed to fit in double hung windows only.
•The window opening can be between 26 inches and 38 inches wide.
•You will need an electrical outlet within five (5) feet of the center of the window.
•You will need a black marker, scissors, a Phillips head screwdriver, and a tape measure to install the unit.
UNPACKING
1. Carefully unpack the contents from the carton and remove the Air Exchange System from the
plastic bag.
2. Place the Air Exchange System
on a clean surface, with the front
grill facing down and slide the Window Sealing Frame off the
back of the unit. See Figure 1.
3. Remove the two Plastic Extender Panels from the plastic bags and
then remove the Foam Insulation Blocks from inside the Plastic Extender Panels.
4.Verify that you received all of the parts shown in Figure 2. If any parts are missing, please contact our consumer service depart- ment at
INSTALLATION
You must install the Window Sealing Frame into the track for your lower window sash before loading the Air Exchange System into the Window Sealing Frame.
1.Measure the frametrack for your lower window sash, at its widest point. See Figure 3.
Write your measurement here:____________
You may close the window temporarily.
2.If your window has a screen or storm window, measure the dis- tance between the front of the window (the side facing inside) to the screen or storm window. If that measurement is less than five (5) inches, you will need to remove the screen or storm win- dow before you can install the Window Sealing Frame.
3.Place the Window Sealing Frame on a flat surface,
4.Place the Plastic Extender Panel stamped LEFT, on the left side of the Window Sealing Frame and the Plastic Extender Panel stamped RIGHT on the right side. See Figure 5.
5.Slide the Plastic Extender Panels down into the guides on the sides of the Window Sealing Frame and press down gently until the Plastic Extender Panels click into place. See Figure 6.
Figure 3
Figure 4 Locking Clamp
Figure 5 |
|
Left Extender | Right Extender |
Panel | Panel |
Figure 6
7.Use the black marker to mark the number on each Plastic Extender Panel that is closest to (but not greater than), the measurement you recorded in Step 1. For example, if your win- dow is 33 inches wide, mark the number 32. See Figure 8.
8.Snap off each segment of the front of the Plastic Extender Panel
with a higher number than you |
|
|
Figure 8 |
| |
marked. If you marked 32 in |
| |
|
| |
step 8, you only will remove the |
|
|
segments for 38, 36 and 34 and |
|
|
three segments from the back of |
|
|
the Plastic Extender Panel. Use |
|
|
a forward and backward motion |
|
|
to remove the excess sections |
|
|
|
| |
along the scored indications. |
|
|
Figure 9 |
| |
See Figure 9. Remove the same |
| |
|
| |
number of segments from the |
|
|
back of the Plastic Extender |
|
|
Panel. |
|
|
9.Repeat this process on the other |
|
|
Plastic Extender Panel. |
|
|
10.Install the Foam Insulation |
|
|
|
| |
Blocks into the Plastic Extender |
|
|
Figure 10A |
| |
Panels. Note that the Foam |
| |
|
| |
Insulation Blocks are divided into |
|
|
vertical segments of various |
|
|
widths. The foam is installed |
|
|
with these segments oriented |
|
|
vertically. See Figure 10A. Insert |
|
|
a Foam Insulation Block into the |
|
|
|
| |
right Plastic Extender Panel. For |
|
|
proper fit, the foam should be | Figure 10B |
|
only slightly wider than the |
|
|
Plastic Extender Panel. If the |
|
|
foam is the exact size, rotate the |
|
|
foam block to utilize the |
|
|
foam block on the opposite | Small |
|
side. Reinstall the foam into the | Block | Large Blocks |
Plastic Extender Panel. See |
|
|
|
| |
Figure 10B. |
|
|
the Window Sealing Frame.
17.Tighten the locking screw using a Phillips head screwdriver. Be careful to not over tighten. See Figure 14.
18.Install the appropriate window sill J- Hooks into the Window Sealing Frame. (See the parts list.) Slide the
NOTE: These hooks may not fit some older window moldings.
19.Install the Sash Insulation Strip as shown in Figure 16.
20.Before installing the Air Exchange Unit, verify that:
a)All foam strips are in place and that there are no visible gaps.
b) The window sash is firmly closed against the foam strip on top of the Window Sealing Frame.
c)The locking clamp tightly grips the window sash.
d)The foam blocks are tightly sealed against the window frame.
e)If used, the window sill
f)Sash Insulation strip is in place.
g)Use the extra foam strips or segments to fill in any visible gaps. 21.Slide the Air Exchange Unit into the Window Sealing Frame and
push until it locks (clicks) into place.
22.For maximum efficiency, you will need to know the size of the room in square feet. (Measure room length and width in feet and multiply. Length X Width=Room Size in Sq. Ft.)
NOTE: When you use the unit for the first time, there may be a slight residual odor from the manufacturing process. This will disap- pear with use.
For best efficiency, we recommend that you program your system to the size of your room.
4.Refer the room measurement you made in step 22 of the Installation Instructions.
Your room is:
Small if it is 90
5.Press and hold the Mode button (2) and the Heat Balance but- ton (3) for three seconds, until the word small flashes.
6.Release the Mode button (2) and press the Heat Balance button
(3)until the desired room size is displayed.
The unit has three motor speeds plus OFF: Normal, Low, Turbo, OFF.
Press the mode button (2) repeatedly until the desired motor speed is displayed. The Air Exchange System is equipped with a Heat Balance setting. When this setting is on, the system equalizes the outside air it draws in to the air temperature of the room.
To Turn on the Heat Balance setting: Press the Heat Balance button (3) once.