Bionaire instruction manual U.K. and IRELAND, BASF17VRC

Models: BASF17V

1 2
Download 2 pages 2.58 Kb
Page 2
Image 2
U.K. and IRELAND

BASF17V/17VRCIUK04EM1.qxd 12/10/04 09:21

U.K. and IRELAND

PLEASE READ AND SAVE THESE

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic safety precautions should always be taken including the following:

Use the fan only for purposes described in the instruction manual.

To protect against electrical shock, do not immerse the fan, plug or mains cable in water or spray with liquids.

Close supervision is necessary when any appliance is used by or near children.

Unplug from the electrical outlet when not in use, when moving the fan from one location to another, before putting on or taking off parts and before cleaning.

Avoid contact with any moving parts.

Do not operate in the presence of explosives and/or flammable fumes.

Do not place the fan or any parts near an open flame, cooking or other heating appliance.

Do not operate any appliance with a damaged mains cable, plug, after the appliance malfunctions, or has been dropped/damaged in any manner.

The use of attachments not recommended or sold by the appliance manufacturer may cause hazards.

Do not let the mains cable hang over the edge of a table or counter, or come into contact with hot surfaces.

To disconnect from the electrical supply, grip the plug and pull from the wall outlet. DO NOT pull on the mains cable.

Always use on a dry, level surface.

Do not operate without the fan grills properly in place.

This product is intended for household use ONLY and not for commercial or industrial applications.

Should the appliance stop working, first check the fuse in the plug (UK only) or fuse/circuit breaker at the distribution board is operating, before contacting the manufacturer or service agent.

If the supply cord or plug is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid hazard.

The appliance contains no user serviceable parts and should the product suffer damage or breakdown it must be returned to the manufacturer or its service agent.

Page 4

Do not use outdoors.

The fan should not be operated without its base fitted.

The fan should not be operated laying on its side.

ASSEMBLY INSTRUCTIONS (See Fig. 1 and 2)

Base and pole

1.Slide the main pole (A) on the cross base (B), making sure the alignment of four holes. Then use four cross base screws (C) to lock them together.

2.Slide the stand base sheath (D) into the main pole.

3.Unscrew the pole extension screw (E) around the top of the main pole and raise the chrome extension pole (F) to its full height. Retighten the pole extension screw.

4.Take the fan head assembly (G), slacken the fixing screw (H) and insert the neck of the fan head assembly onto the pole.

Retighten the fixing screw.

Head and guard

5.Unscrew the fan blade securing screw (I).

NOTE: THIS SCREW HAS LEFT HANDED THREAD AND THEREFORE IS REMOVED BY TURNING CLOCKWISE. Unscrew the rear grill mounting nut (J).

6.Position the rear grill (K) over the motor shaft (L) making sure the notches (M), 2 at the top and 1 at the bottom of the rear grill, fit over the corresponding prongs (N) on the motor housing.

7.Please make sure the rear grill fits securely against the motor housing before securing the rear grill in its place using the rear grill mounting nut (J). Turn this nut clockwise and tighten firmly.

8.Slide the fan blade (O) with the hollowed interior of the blade facing toward the rear grill, firmly onto the motor shaft. The top of the motor shaft should lie even with the centre of the fan blade.

9.Now use the securing screw (I) to lock the blade into place. NOTE: THIS SCREW HAS A LEFT HANDED THREAD AND THEREFORE TIGHTENS ANTICLOCKWISE. Ensure the screw is tight but do not overtighten.

10.Centre the front grill (P) by aligning the Bionaire logo on the logo plate so that it is horizontal and parallel with the floor. Then, holding the front grill against the rear grill, hook the top of the grill ring over the to of the rear grill. Gently push the two parts of the grill together until the clips around the

grill ring snap into position, holding the grill together. The grill ring must fit evenly around the front and rear grills. If it does not, remove the front grill and check the alignment of the ring on the front grill.

11.Secure the guard using the screw (Q), washer (R) and clip (S) by inserting the screw, from the front, through the hole in the bottom of the guard ring. From the back, put the washer and clip, which has a threaded hole, onto the screw, ensuring the clip is the correct way to fit into the recess on the fan ring. Tighten the screw fully but do not overtighten.

OPERATING INSTRUCTIONS

1.Set fan on a dry, level surface.

2.Plug cord into any standard 220-240 volt outlet. Please make sure the speed control is in the off position.

For BASF17V only

1.The SPEED is adjusted by pressing the Control Pad button (W) to the desired setting:

Off (O) - High (III) - Med (II) - Low (I)

2.The OSCILLATION control (T) is located on the top of the fan motor housing. To start oscillation, push the control know down. To stop oscillation, pull the control knob up.

For BASF17VRC only

REMOTE CONTROL

The Remote Control requires 2 AAA batteries for operation.To install the batteries (not included), simply depress the back of the remote, with your thumb in the indentations, and remove the cover. Insert the batteries according to the diagram shown inside. Replace the cover.

All function keys are enabled after pressing the On/Speed key, using the Remote Control unit

(V) or the Control Pad (W).

On/Speed ( BASF17V )

1.To turn the fan On press the On/Speed button. The fan will start to operate at the low speed. You may now choose alternative settings.

2.The fan will be turned Off when you press the Off ( BASF17VRC ).

3By pressing the On/Speed button, you can choose 3 different speeds; successive presses of the On/Speed button cycles the fan through the 3 speeds available.

4The LED lamp on the Control Pad indicates the selected speed stage (III-II-I).

Timer ( Manual background )

1 You can choose different timer stages by

pushing the Timer button.

2The LED lamp on the Control Pad indicated the selected time in hours. After the selected time the fan will stop automatically.

3If no timer LED lamps are lit, the fan will run constantly.

4The memorized time displayed on the keypad is cumulative, i.e. if the 1 hour and 0.5 hour LEDs are lit the fan will switch off after 1.5 hours. The maximum memorized time is 7.5h, each press of the Timer button adds 0.5 of an hour.

Oscillation ( Manual backgroundManual backgroundManual background )

By pressing the Oscillation button, the fan begins to oscillate. Re-press the button to stop.

Breeze Mode ( Manual background )

By pressing the Breeze Mode key, different functions can be chosen.

1.Natural Breeze Mode ( Manual background )

(press Breeze Mode button once).

The Mode LED flashes and the fan operates at different speed stages alternately, to imitate a natural breeze. To de-activate the Natural breeze mode function switch the fan off.

2.Sleeping Breeze Mode ( Manual background )

(press Breeze Mode button twice) Sleeping breeze mode can be used in association with the Timer (see above Timer section for details). By setting different timer durations at Sleeping breeze mode, the fan operates at decreasing speed stages until the memorized timer duration is reached. The LED lamp is continuously on. To de-activate the Sleeping breeze mode function switch the fan off.

ADJUSTMENT INSTRUCTIONS Fan Head Tilt-Adjustment

1.To change the tilting angle of the fan head, simply loosen the tilt-adjustment knob (U).

2.Move the fan head to the desired angle and firmly tighten the tilt-adjustment knob (U) to lock into place.

Height adjustment

Follow these instructions to adjust the height of the fan.

1.Turn the pole locking knob (E) anticlockwise to loosen the pole.

2.Adjust the pole to the desired height and firmly tighten the locking knob in a clockwise direction.

CLEANING AND MAINTENANCE

Always unplug the fan before cleaning or disassembly.

Do not allow water to drip on or into the fan motor housing.

BASF17V

 

J

L

T

Fig. 1

 

 

 

 

 

 

 

 

U

 

 

 

 

G

 

 

 

N

H

 

 

 

 

 

 

 

K W

F

P Q S R I

O

M

E

 

 

 

 

A

 

 

 

 

D

 

 

 

 

B

BASF17VRC

 

 

 

C

 

 

 

 

Fig. 2

 

 

 

 

 

 

J

L

 

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundU

G

Manual backgroundManual backgroundN Manual background H

F

P Q S R I O M K W Manual background E A

Manual backgroundManual background D

VB

Manual background C

Page 2
Image 2
Bionaire instruction manual U.K. and IRELAND, BASF17VRC