Troubleshooting
WARNING:
To reduce the risk of fire, electric shock or injury unplug from outlet before servicing.
SmartTemp™ Ready Light does not illuminate. |
| |
| Possible Causes | Remedies |
| The SmartTemp™ switch is | Turn On the SmartTemp™ switch. |
| not turned ON. |
|
The machine Power Switch is not turned ON.
Both switches must be ON to activate the SmartTemp™ Ready Light.
SmartTemp™ Power Switch does not illuminate.
Possible Causes | Remedies |
The machine Power Switch is not turned ON.
Turn On the SmartTemp™ switch.
Both switches must be ON to activate the SmartTemp™ Ready Light.
Reduced spray or no spray. |
|
Possible Causes | Remedies |
Bladder may be empty. SmartMix® Bottle may be empty. The filter may be clogged.
Tanks may not be seated properly. Pump may have lost prime.
Refill tank with hot tap water. Fill with BISSELL chemical. Clean out filter, page 14.
Turn power OFF; remove and reseat tanks. Turn power OFF; after 1 minute turn ON and depress trigger.
The Pump Belt may be broken. | Turn the machine OFF and unplug from the outlet. | |
| To check if a Pump Belt has broken, you will need | |
| a flat head | screwdriver. Insert the blade end |
| into the lower slot of the Belt Access door to release | |
| the lower snap. If necessary, insert the blade end | |
| into the upper slot to release the upper snap. | |
| Examine for belt breakage. You should be able to | |
| see the Pump Belt looped around the white pulley. | |
| If it is broken or missing, please refer to | |
| Part Numbers and Descriptions on page 17 | |
| before calling Customer Service. | |
| Complete installation instructions will accompany | |
Lift Here | the replacement belt. | |
|
| |
Insert |
|
|
Screwdriver |
|
|
Blade Here |
|
|
15