9
ENGLISH
Cleaning the cyclonic filters (fig. I & J)• Remove and empty the dust bowl.
• Twist the dust bowl end cap (19) anti
clockwise.
• Lift off the dust bowl end cap.
• Lift out the cyclonic filter (20).
• Remove the inlet filter (21) from the cyclonic
filter (20).
• Remove the foam insert (22) from the inlet
filter (21).
• Brush all parts with with a soft brush or wipe
with a damp cloth.
Warning! Ensure all parts are completely dry
before reassembly.
• Insert the foam insert (22) into the inlet filter
(21).
• Insert the inlet filter (21) into the cyclonic filter
(20).
• Insert the cyclonic filter (20) into the dust
bowl (1).
• Place the dust bowl end cap (19) onto the
dust bowl and twist it clock wise to lock into
place.
• Refit the dustbowl to the appliance.
Cleaning the exhaust filter(fig. K)• Twist the exhaust filter cover (23)
anti-clockwise then pull off.
• Remove the Exhaust filter (24).
• Brush all parts with with a soft brush.
Warning! Ensure all parts are completely dry
before reassembly.
• Refit the exhaust filter (24).
• Re-fit the exhaust filter cover (23) and twist it
clockwise to lock it into place.
Clearing a blockageIf the appliance becomes blocked.
• Switch off and unplug the appliance.
• Place the appliance on its side.
• Twist the inspection cover anti-clock wise
and remove it from the bottom of the
appliance.
• Carefully clear the blockage.
• Re-fit the inspection cover and twist it
clockwise to lock it into place.
Mains plug replacementIf a new mains plug needs to be fitted:
• Safely dispose of the old plug.
• Connect the brown lead to the live terminal in
the new plug.
• Connect the blue lead to the neutral terminal.
Warning! Follow the fitting instructions supplied
with good quality plugs. Recommended fuse:
13A.
Technical Data VM2825 (Type 02)
Voltage Vac 220 - 240 50/60Hz
Power (Nominal) W 1800
Power (Max) W 2000
Weight kg 5.5