3.3 Optical Connections

FIBER LINK

NOTE

Use RG59/U coaxial cable (part number ETN59-BNC) between the video equipment and the fiber units. The video equipment and the fiber unit should be no more than 100 ft. (30.5 m) apart.

Terminate the coaxial cable with a female BNC and connect it to the fiber unit. Repeat for both ends of the link.

3.3 Optical Connections

The standard optical connector on the Fiber Link is ST. Connect the preterminated fiber to the two fiber units.

3.4 Power Connections

All standalone modules are equipped with removable screw-terminal connectors for power input.

1.Identify the power connector and remove it from the module.

2.Make sure the power supply is not connected to any power source, and strip approximately 14 inch (0.6 cm) of insulation from the ends of the cable.

3.While observing correct polarization of the cable (see Table 3-1), insert one lead into one of the screw sockets and tighten the screw. Repeat for the other conductor. Confirm the security of the connection with a light pull on the cable.

Table 3-1. Pin and Connector Functions

Pin No.

Function

Connector

Function

3

+12 to 16 VDC

BNC

Video, Data, and Genlock Sync

2Alarm/+5 VDC

1Ground