FIBER LINK

Electrical

Input Voltage—AC455A-TX-R2: 12 to 16 VAC, 12 to 14 VDC; AC456A-RX-R2: 13.5 to 16 VDC

Input Power Frequency—50 to 60 Hz

Current Requirement—AC455A-TX-R2: 300 mA; AC456A-RX-R2: 380 mA

Power Consumption—6 W

Heat Equivalent—0.3 BTU/min., 0.09 cal/min.

NOTE

The heat equivalent represents the conversion of all input power to heat. The actual heat generated will be less.

Environmental

Temperature—Operating: 32 to 122°F (0 to 50°C); Storage: -40 to +185°F (-40 to +85°C)

Mechanical

Enclosure—Transmitter: 4 x 4 (10 x 10 cm); Receiver: 501R

Construction—Aluminum enclosure with black semigloss paint finish

Mounting Method—(4) No. 6 (3-mm) screws

Size—AC455A-TX-R2: 1.2"H x 4.6"W x 4.7"D (3 x 11.7 x 11.9 cm), including connectors; AC456A-RX-R2: 1.2"H x 6.3"W x 9.8"D (3.2 x 16.2 x 24.9 cm), including connectors

Weight—AC455A-TX-R2: 0.7 lb. (0.3 kg); AC456A-RX-R2: 1.6 lb. (0.7 kg)

9

Page 10
Image 10
Black Box AC455A-TX-R2, AC456A-RX-R2 manual Electrical, Environmental, Mechanical