Black Box CDTT300A-7-R5, CDTE300A-7-R5 manual No. Fault Corrective Blinks Indication Action

Models: CDTT300A-7-R5 CDTE300A-7-R5

1 24
Download 24 pages 3.34 Kb
Page 21
Image 21

CHAPTER 4: Using the CD Network Tower

 

CD Network Tower Status LEDs

No. of

Fault

Corrective

Blinks

Indication

Action

0

Solid red

Return to dealer; unit failed power-on self-test.

1

Blinking yellow

No network found; check network cabling.

2

Blinking yellow

Boot server not set; configure CD Network Tower.

3

Blinking yellow

Boot filename not set, configure CD Network Tower.

4

Blinking yellow

Boot server not found; configure CD Network Tower.

5

Blinking yellow

Boot filename bad or not found. Verify that SYS:\LOGIN

 

 

directory on boot server has .IMG file shown in More

 

 

Info—Details in the Tools menu.

6

Blinking yellow

SCSI terminator power. Use “Fileserver Information”

 

 

dialog to display detailed SCSI errors (check SCSI

 

 

cables). Select the attached CD Network Tower, then

 

 

select More Info—Details from the Tools menu.

7

Blinking yellow

SCSI bus hung. Use “Fileserver Information” dialog to

 

 

display detailed SCSI errors (check SCSI cables).

 

 

Select the attached CD Network Tower, then select

 

 

More Info—Details from the Tools menu.

9, 10

Blinking red

Call for technical support.

 

Solid yellow

Unattached CD Network Tower. Use DiscView to

 

 

display error. Select the unattached CD Network Tower,

 

 

then select More Info from the Tools menu.

21

Page 21
Image 21
Black Box CDTT300A-7-R5, CDTE300A-7-R5 manual No. Fault Corrective Blinks Indication Action