TECH SPECS

General:

Certification — FCC, CE

Data Buffer — 32 KB, dynamically allocated

Data Format — 7 or 8 data bits, 1 or 2 stop bits; parity odd, even, mark, space, or disabled

User Controls — Power switch (external), IEEE and Serial parameter switches (internal); Jumper selection of RS-232 or RS-422 operation (internal)

Interface — IEEE 488; RS-232/RS-422

Indicators — (5) LEDs: Talk, Listen, Send, Receive, Power

Environment — 32 to 122°F (0 to 50°C); Up to 70% to 95°F (35°C) relative humidity; Linearly derate 3% relative humidity/degrees C from 95 to 122°F (35 to 50°C)

Power — Input: 100–240 VAC, autosensing, 50–60 Hz, 0.5 A maximum; Output: 9 VDC, 15 W maximum, 1.7 A

Size — 2.7"H x 5.4"W x 7.5"D (6.9 x 13.7 x 19.1 cm) Weight — 2.5 lb. (1.1 kg);

Power supply: 0.9 lb. (0.4 kg)

IEEE 488 Interface:

Implementation — C1, C2, C3, C4, and C28 controller subsets; Serial to IEEE: SH1, AH1, T6, TE0, L4, LE0, SR1, RL0, PP0, DC1, DT0, E1

Terminators — Selectable CR, LF, LF-CR, and CR-LF with EOI Connectors — Standard IEEE 488 connector with metric studs

Serial Interface:

Character Set — Asynchronous bit serial

Data Format — Selectable 7 or 8 data bits; 1 or 2 stop bits; odd, even, mark, space, and no parity on transmit

Duplex — Full with Echo/No Echo EIA RS-232CAB, BA, BB, CA, CB

EIA RS-422ABalanced voltage on TxD and RxD Input Voltage — ±3 volts minimum; 15 volts maximum

Output Voltage — ±5 volts minimum (RS-232C); 5 volts typical (RS-422A) Serial Control — Selectable CTS/RTS or X-ON/X-OFF

Speed — Selectable 110, 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 19,200, and 57,600 bps

Terminators — Selectable CR, LF, LF-CR, and CR-LF Connectors — DB25 male, DCE configured

Why Buy From Black Box?

Exceptional Value. Exceptional

Tech Support. Period.

Recognize any of these situations?

You wait more than 30 minutes to get through to a vendor’s tech support.

The so-called “tech” can’t help you or gives you the wrong answer.

You don’t have a purchase order number and the tech refuses to help you.

It’s 9 p. m. and you need help, but your vendor’s tech support line is closed.

According to a survey by Data Communications magazine, 90% of network managers surveyed say that getting the technical support they need is extremely important when choosing a vendor. But even though network managers pay anywhere from 10 to 20% of their overall purchase price for a basic service and support contract, the technical support and service they receive falls far short of their expectations—and certainly isn’t worth what they paid.

At Black Box, we guarantee the best value and the

best support. You can even consult our Technical Support Experts before you buy if you need help selecting just the right component for your application.

Don’t waste time and money—call Black Box today.

Item

Code

To link an RS-232 device to a 488 bus, order…

 

232↔488 Interface Converter

IC026A-R3

You may also need…

 

IEEE 488 Cable (with Molded Connectors)

EXN02M

6.6-ft. (2-m)

13.1-ft. (4-m)

EXN04M

Individually Shielded Low-Capacitance Cables,

ERN04A

Extra Distance, PVC, 4-Conductor

6/14/07

724-746-5500

blackbox.com

#10470

 

 

4 of 4

Page 4
Image 4
Black Box IC026A-R3 manual Tech Specs, General