Industrial Grade 4-Port USB Hub
Table 1. LED indicators.
LED Type | State | Description | |
|
|
| |
|
| The hub is running on USB power. | |
| ON | External power is not applied. The hub | |
| can supply up to 100 mA power per | ||
|
| ||
*USB Power |
| downstream port. | |
|
|
| |
| OFF | The hub is either using external power, | |
| or no power is present. | ||
|
| ||
|
|
| |
|
| External power is applied and an active | |
| ON | host connection exists. The hub will | |
External Power |
| provide 500 mA per downstream port. | |
|
| ||
|
|
| |
| OFF | The hub is bus powered (ICI200A only) | |
| or no power is present (ICI202A). | ||
|
| ||
|
|
| |
| ON | Port is active and ready for use. | |
Port LEDs |
|
| |
OFF | Port has a fault. Power may need to be | ||
| |||
| cycled. | ||
|
| ||
|
|
|
*USB Power LED is on ICI200A model only.
Troubleshooting
Black Box Tech Support: FREE! Live. 24/7. Tech support the way it should be.
Great tech support is just 30 seconds away at
Troubleshooting (Continued from page 5)
Problem: Can I use USB 1.1 and USB 2.0 devices together?
Solution: Yes. USB 2.0 is
ICI200A
ICI202A
Industrial Grade 4-Port USB Hub
Quick Start Guide
Isolated and non-isolated models available.
Problem: The hub is installed, but a downstream device isn’t working.
Soluton: Some USB devices get their power from the USB cable. If you are using the ICI200A without an external power supply, it will only provide 100 mA to the downstream ports. If your devices need more power, connect an external power supply to the ICI200A. It will then provide 500 mA to the down- stream ports.
Problem: Do I need drivers for the hub?
Solution: No, the operating system will detect it and install it automatically.
Customer
Support
Information
Order
(outside U.S. call
FREE technical support
24 hours a day, 7 days a week: Call
fax
Mailing address: Black Box Corporation 1000 Park Drive Lawrence, PA
Web site: www.blackbox.com
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS.
Problem: How can I be sure it has been installed?
Solution: The new hub will be listed in the Device Manager.
© Copyright 2012. Black Box Corporation. All rights reserved.
Black Box and the Double Diamond logo are registered trademarks of
BBTechnologies, Inc. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
INSTALL IN ACCORDANCE WITH CONTROL DRAWING NUMBER
Page 5 | Page 6 |