Black Box LB9002A-ST-R2 manual Installation, Quick Tip

Models: LB9002A-ST-R2

1 16
Download 16 pages 27.07 Kb
Page 12
Image 12

Express Ethernet Switch

Table 8: Specifications per model

Model

LB9002A-SC/ST

Dimension "W x "D x "H

10 x 5.3 x 1.4

25.4 x 13.5 x 3.6 cm

Weight

2.1lb.

0.9kg

Output

100-250VAC

47-63 Hz

Pwr

7W

Installation

Quick Tip

Install a Black Box Express Ethernet Switch as a plug-and-play device. No special configuration is required. Details below are consistent with the installation of any electronic device

Place the Black Box Express Ethernet Switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:

??The room temperature should be between 32 and 104 degrees Fahrenheit (0 to 40 degrees Celsius).

??The relative humidity should be less than 90 percent, non-condensing.

??Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength.

??Make sure that the switch receives adequate ventilation. Do not block the ventilation holes on the side of the switch or the fan exhaust port on the rear of the switch.

??The power outlet should be within 1.8 meters of the switch.

Connecting to Power

Connect the supplied AC power cord to the receptacle on the back of the switch, and then plug the cord into a standard AC outlet with a voltage range from 100 to 120 VAC. For external power supply units, plug the jack into the DC receptacle on the front of the unit, and plug the power supply unit into a 110~220 AC outlet.

Turn the switch on by flipping the ON/OFF switch on the rear of the unit to the I (ON) position. The O position is OFF.

Connecting to Your Network

If you are making a connection to a server or workstation, be sure that it has a properly installed 100BASE-TX (or 100BASE-FX if the switch does not contain 100BASE-TX ports) network interface card. Connect the RX/TX jacks on the target device to the TX/RX jacks on the switch and the RJ -45 jacks on the target device to the RJ -45 jacks on the switch.

Use the uplink port for connecting to a regular (i.e. non-uplink) port of a hub or another switch. If connecting to an uplink port of a hub or another switch, use any port. There is no uplink issue with fiber ports.

Copper-based cabling

Connect cables to computers or network segments into the RJ -45 ports on the front of the switch.