Black Box LE180A Cable Specifications, Troubleshooting, Contact Us, Copper cables

Models: LE180A 10Base-T Transceiver Stand-Alone model

1 7
Download 7 pages 57.21 Kb
Page 6
Image 6
Cable Specifications

LE180A

Cable Specifications

The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications.

Copper cables

Category 3: (minimum requirement)

 

Gauge

24 to 22 AWG

Attenuation

11.5 dB/100m @ 5-10 MHz

Maximum cable distance:

100 m

Category 5: (recommended)

 

Gauge

24 to 22 AWG

Attenuation

22.0 dB/100m @ 100 MHz

Maximum cable distance:

100 m

Straight-through or crossover twisted-pair cable may be used.

Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.

Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .

RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-

Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

Do not use flat or silver satin wire.

Troubleshooting

If the transceiver fails, determine the answer to the following questions:

1.Is the status LED flashing?

NO

Verify that the AUI device is turned ON.

Verify that the AUI cable from the transceiver to the AUI device port is installed properly.

Contact Tech Support: 724 746-5500.

YES

Go to step 2.

2.Is the RX LED flashing (receiving data)?

NO

Is the LED ON Solid?

Check twisted pair cable for proper connection

Contact Tech Support: 724 746-5500.

Yes

Go to step 3.

3.Is the TX LED ON?

NO

Check twisted pair cable for proper connection.

Is the LED flashing (transmitting data)?

Restart the hardware to force re-initialization.

Contact Tech Support: 724 746-5500.

Yes

Contact Tech Support: 1724 746-5500.

10 Black Box Network Services, 724-746-550, www.blackbox.com

LE180A

Contact Us

Black Box, Headquarters

1000 Park Drive

Lawrence, PA 15055-1018

By Telephone:

877-877-2269

By Fax:

724-746-0746

By E-mail:

info@blackbox.com

Technical Support

Technical support is available 24 hours a day.

U.S.A:

724 746-5500

Fax:

800-321-0746

Website:

www.blackbox.com/Tech_Support/Index.aspx#

 

 

 

Declaration of Conformity

NETWORK SERVICES

Name of Mfg:

Black Box Network Services

 

Black Box, 1000 Park Drive Lawrence, PA 15055-1018 U.S.A.

Model:

LE180A Transceiver

Part Number(s):

LE180A

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the LE180A Transceiver to which this declaration refers is in conformity with the following standards.

EN55022:1998 + A1:2000 + A1:2003 EN 55024:1998 + A1:2000 + A2:2003

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

 

May, 2007_____

Stephen Anderson, Vice-President of Engineering