LE180A
Installation
Switches
The LE180A has a
SW1 | SW2 |
SW3 | |
|
Front
Figure 6: LE180A Three-Position Switch
The following describes the switch settings:
SW1 = SQE test: UP is enabled/DOWN is disabled
SW2 = Link test: UP is enabled/DOWN is disabled
SW3 = Duplex: UP is half/DOWN is full
SQE test
The transceiver is shipped from the factory with the SQE test switch enabled. SQE (Signal Quality Error) is the IEEE term for collisions. Depending on the Ethernet device attached to the AUI connector, set the SW “1” to the DOWN position to disable the SQE test function or to the "UP" position to enable the test.
The SQE Test (heartbeat) is a means of detecting a transceiver’s inability to detect collisions. Without this test, it would not be possible to determine if the collision detector is operating properly. The SQE test starts by generating a test signal on the collision pair from the transceiver (or its equivalent) following every transmission on the network. It does not generate any signals on the common medium.
Additionally, IEEE 802.3 specifications state that IEEE 802.3 compliant repeaters must not be attached to transceivers that generate the heartbeat.
Link test
For UTP port connection, the LE180A implements the link integrity test functions as specified in the IEEE 802.3
LE180A
Installation -- Continued
Connecting to a Device AUI port
The LE180A can connect to any Ethernet device with an AUI port. To connect to a device with an AUI port, an AUI cable or direct connection is required. See Figure 7.
AUI Cable Length 50 Feet Maximum |
AUI
Black Box
Transceiver
Figure 7: LE180A Connected to an AUI Device Port
Connecting to an RJ-45 device jack
IMPORTANT: If the transceiver is attached to an Ethernet repeater,
To connect the transceiver to a
1.Select an appropriate length UTP cable for the connection.
2.Connect one end of the UTP cable to the
3.Route the free end of the UTP cable to the area where
4.Connect the free end of the UTP cable to an
Hub
|
|
|
| ||
|
|
|
|
| AUI Cable |
|
|
|
|
| |
UTP Cable |
|
| Black Box | ||
|
| Transceiver | |||
|
|
|
|
Figure 8: LE180A Connected to a RJ-45 Device Jack
6 | Black Box Network Services, | Black Box Network Services, | 7 |