Black Box LPJ001A-F, 802.3af PoE Gigabit Injector, 1-Port specifications blackbox.com

Models: LPJ001A-F 802.3af PoE Gigabit Injector, 1-Port

1 2
Download 2 pages 4.24 Kb
Page 2
Image 2
724-746-5500  blackbox.com

© Copyright 2011. All rights reserved.

Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Bluetooth is a registered trademark of The Bluetooth SIG, Inc.Any other trademarks mentioned in this manual are acknowleged to be the property of the trademark owners.

4. Description of LED Functions

 

 

 

 

Table 1. LEDs and their functions.

LED

State

Function

Description

ON, CONNECT,

All three LEDS light

Power up

Upon power-up, all three LEDs will light for two seconds, as

FAULT LEDs

 

 

part of the self-test for the internal microprocessor software.

ON LED

Lights green after

DC output

After two seconds, the ON LED will light green, indicating that

 

two seconds

voltage available

the DC output voltage is available for powering an 802.3af

 

 

 

PoE compliant load.

CONNECT

Lights green

802.3af load

This green LED lights when a compliant load is attached to

LED

 

is attached

the output RJ-45 connector.

 

Blinking

802.3af load

If the load does not comply with 802.3af PoE standards,

 

 

is not attached

then the LEDs will blink a code indicating that the load was not

 

 

 

detected. See Table 2 for code descriptions.

FAULT LED

Lights red

Overload or

 

 

short circuit

 

Lights red for

Power supply is

 

two seconds,

trying to re-detect

 

then goes off

a valid load

If a fault, such as an overload or short circuit, occurs, then the red FAULT LED lights. See Table 2 for code descriptions.

The red LED will light for two seconds and then go off as the power supply tries to re-detect a valid load. If a compliant

802.3af PoE load is NOT detected, the LED will indicate the problem as described in Table 2.

 

Table 2. Failure detection codes.

Code

Name

Description

1

Incorrect resistive signature

The green CONNECT and red FAULT LEDs blink three times.

2

Incorrect capacitive signature

The green ON LED blinks three times.

3

Incorrect V offset

The green CONNECT and green ON LEDs blink three times.

4

Unstable current measurement

The green ON LED blinks three times.

5

Low voltage sensed during detection (overload)

The red FAULT LED blinks three times.

NOTE: After the LEDs blink three times, the power injector will continue to try to detect a valid load. Until the correct load is applied, the LEDs will continue to blink. If an open circuit is connected to the output RJ-45 connector, then the LEDs will not blink but the power injector will continue to try to detect a valid load.

LPJ001A-F, version 2

FREE, live, 24/7 Tech Support is just 20 seconds away.

724-746-5500 blackbox.com

Page 2
Image 2
Black Box LPJ001A-F, 802.3af PoE Gigabit Injector, 1-Port specifications blackbox.com