Black Box SC121A, SC120A-R2 manual Configuration and Operation

Models: SC121A SC120A-R2

1 53
Download 53 pages 19.06 Kb
Page 32
Image 32

CHAPTER 5: Configuration and Operation

i. Report Temperature:

example command: <cr>//t<cr>

example report: //t+19.5 +19.5 = +19.5˚C, +67˚F

j. Report SCSI-Bus Performance: example command: <cr>//P<cr> report format: //P<aabb1122><cr>

For ports A, B, 1, and 2 respectively, aa, bb, 11, and 22 = ASCII representations of 8-bit hexadecimal values from 00 to FF, where

00 represents 0% busy (completely idle) and FF represents 100% busy

k. SCSI-Bus Inactivity to SCSI Report: example command: <cr>//I<cr> report format: 1111 2222

For ports 1 and 2 respectively, 1111 and 2222 = ASCII representations of 16-bit hexadecimal values that express the length of time in tenths of seconds that the port has been inactive (not transmitting or receiving data). For example, “0A73” = 0 x 4096 (163) + 10 x 256 (162) + 7 x 16 + 3 tenths of seconds = 267.5 seconds = 4 minutes 27.5 seconds.

l. Yank on SCSI Reset line:

example command: <cr>//B2Y<cr>

report: none

m. Enable/Disable Audible Alarm:

example command: <cr>//OAx<cr> [x = ASCII 1 or 0]

x:0 = enable alarm, 1 = disable alarm report: none

n.Set Serial-Port Baud Rate:

example command: <cr>//OBxy<cr> [x and y = ASCII 1 or 0]

x:0 = COM1, 1 = COM2

y:0 = 9600 bps, 1 = 19,200 bps report: none

o.Set Mode of Serial (Comm) Port for RS-232 Port 2: example command: <cr>//OCx<cr> [x = ASCII 1 or 0]

x:0 = use Port 2 for daisychaining, 1 = use Port 2 as a second serial port report: none

Note: This command has no effect if the LAN port is enabled, which disables RS-232 Port 2.

31

Page 32
Image 32
Black Box SC121A, SC120A-R2 manual Configuration and Operation