Image 29

TROUBLESHOOTING

 

PROBLEM

LOOK FOR

Unit will not come on

- Power switch is off.

 

- Unit not plugged in.

 

- Main power supply off.

 

- Bad electronic module.

 

- Bad low water control.

 

- Bad spark igniter.

 

- Bad intermittent pilot burner.

 

- Fuse in unit blown.

Unit will turn on electrically but will not heat

- Lockout has occurred.

 

- Thermostat not on.

 

- Gas control valve off.

 

- Main gas supply off.

 

- Low water.

 

- Bad thermostat.

 

- Bad pressure switch.

 

- Bad gas control valve.

 

- Bad spark igniter.

 

- Bad igniter cable.

 

- Bad intermittent pilot burner.

 

- Faulty gas control.