TROUBLESHOOTING:

 

PROBLEM

LOOK FOR

Excessive flame rollout on ignition, carboning

- Natural gas unit on propane.

 

- Excessive gas pressure.

 

- Incorrect orifice size.

 

- Faulty regulator in gas control.

Unit slow to preheat and slow to recover

- Propane gas on natural.

 

- Low gas pressure.

 

- Incorrect orifice sizes.

 

- Loss of vacuum.

 

- Faulty regulator in gas control.

Unit continuously locks out

- Pilot gas adjusted too low.

 

- Excessive draft condition.

 

- Excessive steam around bottom of unit

 

- Faulty transformer.

 

- Faulty electronic module.

 

- Faulty ignitor cable.

 

- Faulty spark igniter.

 

- Faulty gas control.