SERVICING INSTRUCTIONS — PLUMBING

FUNCTION

1.Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller.

NOTE: The solenoid has an internal strainer. To clean the

strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the cap, inlet fitting and washer. With pliers, grasp the bar of the strainer and pull straight out. Wash any debris from the strainer. Note orientation - DO NOT reverse strainer.

Reassemble and reinstall. Turn water supply back on.

2.Water enters the tank (2) thru the fill tube (16). Water is heated in the tank by the heating element (15).

3.The tank lid (9) is sealed around the edge with a gasket (6), and is secured by 3 clips (10).

FILL PORT

VENT PORT

BREW PORT FAUCET PORT

HEATER

PORTS

WATER TANK

4.Heated water is dispensed to the brew head through the brew tube (14), brew solenoid (18), and spout of the brew fitting (19). The brew solenoid is energized during the brew cycle by the controller.

NOTE: The flow rate of the brew solenoid is factory set. DO NOT adjust.

5.Hot water is sprayed over the coffee grounds by the spray disc (24), which is sealed to the brew head by a gasket (23).

6.The tank is vented through the vent elbow fitting (40) and vent tubes (11 & 13).

7.Water for the hot water faucet (1) is supplied from the tank through the faucet supply tube (12).

SOLENOID

STRAINER

 

 

(note orientation

 

GASKET

DO NOT REVERSE)

 

WASHER

LID

 

CLIP

 

 

INLET

 

 

 

 

FITTING

TANK

 

CAP

 

 

FLOW

CONTROL (installed)

LID GASKET

FILL

SOLENOID

 

12

Page 14
Image 14
Bloomfield 2074L, 2072FRL, 2012, 2016EX, 2074FRL, 2072L owner manual Servicing Instructions Plumbing, Function