SERVICING INSTRUCTIONS - ELECTRICAL

SERVICING INSTRUCTIONS - ELECTRICAL

WARNING:

RISK OF INJURY

The following servicing sections are for operator reference only. All servicing and/or repairs must be performed by a qualified technician

FILL

 

 

 

 

 

 

WATER

 

CONTROLLER

LEVEL

 

PROBE

 

 

 

FILL

 

 

 

SOLENOID

HEAT

 

 

 

LINE

BREW

 

 

VOLTAGE

 

WATER

 

TEMP

 

HI-LIMIT

 

TEMP

 

 

T STAT

CONTROLLER

PROBE

TRIAC

 

 

 

HEATING

 

 

 

ELEMENT

 

 

 

BREW

BREW

DRIP OUT

 

 

TIME

TIME

 

 

CONTROLLER

BREW

 

 

 

 

 

 

SOLENOID

 

BREW

BREW

 

 

CANCEL

 

WARMER

QUALITY

 

 

 

 

 

 

TIME

 

 

CONTROLLER

WARMER

 

ELEMENT

 

 

 

 

 

WARMER

 

Reset Hi-Limit Thermostat 240 V & Dual Voltage Units

FUNCTION

1.Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON.

2.Automatic fill is accomplished via a FILL SOLENOID

(32)and a WATER LEVEL PROBE (7). The probe

senses ground through the water in the tank. When the water level falls below the probe and ground is no longer sensed, the CONTROLLER (20) energizes the fill solenoid (32) until the water level again reaches the water level probe.

3.Pressing the BREW key begins the brew cycle. Pressing the CANCEL key at any time during the

brew cycle terminates the brew. The BREW SOLENOID

(18)is energized by the CONTROLLER (20) for a time determined by the BREW TIME setting.

A second brew can be started only after the brew time plus the DRIP OUT time has elapsed.

4.Brew water temperature is controlled via a WATER TEMPERATURE SENSOR (3) and a HEATING ELEMENT (15) controlled by a TRIAC (17) electronic switch. The element is energized according to the sensed water temperature and the BREW TEMP setting.

An over-temperature condition will trip the HI-LIMIT THERMOSTAT (4), de-energizing the heating element. Note: On 120 volt units, hi-limit will automatically reset once the tank has cooled by approximately 30ºF. On 240 volt units and dual voltage units, the hi-limit must be manually reset by pressing the red button after the unit cools.

5.Individual WARMER PLATES (27) are heated by WARMER ELEMENTS (28), which are controlled by the WARMER keys. Pressing a warmer key will turn ON or OFF the corresponding warmer and LED.

MAIN WARMER PLATE is turned ON automatically at the start of a brew cycle.

Because coffee loses its freshness after sitting on a warmer, a quality time function is included. The WARMER LEDS will begin to flash some time after the last brew cycle, based on the QUALITY TIME setting. Note: QUALITY TIMER does not turn off the warmer elements.

6.The unit will revert to the energy-saver mode some time after the last brew, based on AFTER HOURS TIME setting.

14