605 70988 Owners Manual Integrity 5W Decanter Brewer

ACCESS PANELS

TOP PANEL:

Remove top panel to access hot water tank, thermostat, heating elements, brew circuit tubing and faucet tubing.

Top panel is held by two screws at the front and a retaining lip at the rear.

FRONT PANELS:

Remove upper front panel to access timer and hi-limit. Remove button plugs for simple adjustments or reset.

Upper front panel is held by two screws at the bottom and a retaining lip at the top.

SOLENOID DOOR:

Remove solenoid door to access solenoid and tubing connections.

Solenoid door is held by two screws and a retaining lip.

TERMINAL BLOCK ACCESS:

Remove door to access wiring connections

Access door is held by two screws and a retaining lip.

WARMER PLATES:

Warmer plates unscrew counterclockwise to access warmer elements and electrical connections.

SERVICING INSTRUCTIONS

CAUTION:

SHOCK HAZARD

Opening access panels or removing warmer plates on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel.

Fig. 9 Access Panels

11

Page 13
Image 13
Bloomfield 8752 owner manual Servicing Instructions, Access Panels