10.Reconnect brewer to electrical supply and reconnect water supply.

SERVICING INSTRUCTIONS (continued)

605 70988 Owners Manual Integrity 5W Decanter Brewer

7.Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then reinstall lid clamps.

8.Reinstall wiring to heating element and thermostat. Reassemble piping for the faucet. Verify that all internal components are dry, then reinstall the top panel.

10.Reconnect brewer to electrical supply and reconnect water supply.

11.Install the brew chamber without filter paper or grounds. Run at least three full brew cycles and discard all water generated.

12.Brewer is ready to use.

NOTE: Normally, silicone hoses do not need to be delimed. Should deliming hoses become necessary, Bloomfield recommends replacing the hoses.

17