SERVICING INSTRUCTIONS (continued)
Fig. 11 Remove Faucet Supply from Solenoid
Fig. 12 Clean Strainer Screen
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head.
NOTE: Wrench p/n 86660 is designed to allow easy removal of the hoses from the plastic solenoid valve.
IMPORTANT:
Remove water supply flare fitting:
a.Slide the 5/8" end of the wrench over the flats on the inlet fitting of the valve.
b.Hold the wrench to prevent the inlet fitting from turning while installing or removing the inlet water supply flare nut.
Remove braided hose:
a.Slide the 7/16" end of the wrench between the valve body and the white ring on the extreme end of the metal hose fitting.
b.Pressure on the white ring toward the metal ferrule releases the clinch ring, allowing the hose to be easily slid off of the solenoid bypass outlet.
c.Install hose on new valve by pressing end of hose onto bypass outlet until it is fully seated.
Disconnect wiring.
Remove two screws holding solenoid to access door. Reassemble in reverse order.
CLEAN SOLENOID SCREEN
Symptom: Automatic brewer will not flow water.
Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Using
Reinsert screen in solenoid. Be careful to maintain correct orientation. (The OPEN END of the screen goes in FIRST.)
Reassemble in reverse order.
625 75873 Owners Manual Gourmet 1000 Dual Airpot Brewers
14