Outdoor LP Gas Light Model No. GTL702W

Installing LP Gas Tank

To operate you will need (1) 14.1 oz or (1) 16.4 oz LP gas tank.
Insert LP Gas Tank

Place precision filled LP gas tank upright into hole in outdoor gas light body so it is arranged for vapor withdrawal.

Connect LP Gas Tank
WARNING: Only cylinders marked “propane” may be used.
Note: Some 14.1 oz or 16.4 oz LP gas tanks may form frost when near empty.

Line up threads on LP gas tank with those on regulator, insert and rotate LP gas tank clockwise until they fit snugly together. HAND TIGHTEN ONLY. Be careful not to cross threads when screwing in LP gas tank.

Operating Instructions

Checking for Leaks

WARNING: Before using this Outdoor Light, make sure you have read, understand and are following all information provided in the Dangers and Warnings presented on page 2. Failure to follow those instructions can cause death, serious injury or property damage.

Burner Connections

Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.

If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.

WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property.

Please refer to diagram for proper installation.

If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.

Tank/Gas Line Connection

Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.

Make sure control knob is OFF. Attach the LP gas tank.
Spoon leak check solution at all “x” locations

If no bubbles appear after one minute turn control knob to “OFF”, wipe away solution and proceed.

LP Gas

Burner

Connection

venturi

 

LP Gas Valve

Burner

with Orifice

X

Control Knob
Disconnect LP Gas Tank
Rotate LP gas tank counterclockwise until the LP gas tank comes off.
Lighting

1.Make sure there are no obstructions of airflow to the gas unit. Spiders and insects can nest within and clog the burner / venturi tube at the orifice.

A clogged burner tube can lead to a fire beneath the appliance.
2.Control knob must be in the “OFF” position.
3.Attach the LP gas tank.

4.Push in control knob and rotate to “ON” position. This will activate the built-in ignitor and light the burner. If necessary, keep depressing and rotating knob until burner lights.

5.If ignition does not occur in 5 seconds, turn burner control knob to “OFF”, wait 5 minutes, and repeat lighting procedure.

6.Once the burner is lit, hold control knob in for 30 seconds.

7.If burner does not stay lit, turn to “OFF” position and wait 5 minutes and repeat lighting procedure.

8.After lighting, observe the burner flame and flame height matches illustration.

CAUTION: If burner flame goes out during operation, immediately turn the gas “OFF” and open top cap to let the gas clear for about 5 minutes before re-lighting.

Turning Off
1.Remove the LP gas tank.
2.Once the flame goes out, turn the control knob clockwise to “OFF” position.
3.Properly store LP gas tank.
Note: May take up to 5 minutes for flame to extinguish.
4 in.
10 cm.
3 in.
7.5 cm.
2 in.
5 cm.
1 in.
2.5 cm.
0 in.
0 cm.
Burner proper flame height.