Recommended Installation Diagram

off

 

run

2A

 

accessory

 

 

 

 

 

start

 

 

 

Start Key Switch

 

See Wire Size and Fuse Rating Chart for

 

 

 

 

 

LEGEND

 

 

connections of Terminals A and B.

 

 

 

NOTE: To determine wire sizes and fuse

 

Positive

 

 

ratings for all other wires illustrated

Start

Negative

 

 

please visit the Circuit Wizard at

Solenoid

 

 

circuitwizard.bluesea.com

Optional

 

 

 

 

 

 

 

Fuse

 

 

 

 

2A

 

 

 

Auxiliary

10A

 

Start

Battery

 

Battery

Optional

 

 

850 CCA* Maximum

Remote LED

 

 

* Cold Cranking Amperes

 

16 AWG

16 AWG

Auxiliary Battery Priority

 

 

 

 

16 AWG

 

Optional Connection

Wire Size and Fuse Ratings

Wire Size and Fuse Rating Chart (AWG)

 

Wire Size and Fuse Rating Chart (Metric)

Charging Amps

Minimum Wire Size*

Fuse Rating

 

Charging Amps

Minimum Wire Size*

Fuse Rating

≤60

#6

75-90A

 

≤50

10 mm²

75-80A

≤80

#4

100-125A

 

≤70

16 mm²

80-90A

≤100

#2

150A

 

≤90

25 mm²

125-130A

≤120

#1

175A

 

≤110

35 mm²

150A

 

 

 

 

≤120

50 mm²

150-175A

* Larger wire sizes may be required to minimize voltage drop in long wire runs.

For more information please use the Circuit Wizard at www.circuitwizard.bluesea.com

Dimension Drawings

*This installation diagram shows a typical application only. Your application may differ. For further information, please go to www.bluesea.com and navigate to Resources/Application Briefs and Technical Briefs.

*Because the BatteryLink™ ACR is Dual Sensing, terminals A and B are interchangeable. ACR function will not be affected by reversal of the starting and house batteries versus the diagram.

*It is recommended that the ACR be connected directly to your battery positive terminals through appropriately sized fuses. Connecting in a different location such as a battery switch may affect accuracy because of voltage drop along current carrying conductors.

*If you are not knowledgeable about electrical systems, please consult an electrical professional for help with installation.

425 Sequoia Drive Bellingham, WA 98226 USA p 360.738.8230

p 800.222.7617 USA and Canada f 360.734.4195 www.bluesea.com

980011740 Rev.002

Page 2
Image 2
Blue Sea Systems PN 7511, 7611 Recommended Installation Diagram, Wire Size and Fuse Ratings, Dimension Drawings