Marine Electrical Products
ML-RBS
Remote Battery SwitchesPN 7712 / PN 7712B / PN 7712100B
PN 7714 / PN 7714B / PN 7714100B
•Magnetic Latch (ML) - draws very low current continuous and draws moderate current for very short time when changing state
•Silver alloy contacts provide high reliability for switching live loads
•Manual override provides LOCK OFF capability for servicing and ON/OFF control with or without power
•LED output to remotely indicate switch state
•
•Label recesses for circuit identification
•PNs 7712 and 7714 include a Remote Control Switch PN 2155
Specifications | 12V DC | 24V DC |
Cranking Rating | See table below | See table below |
Intermittent Rating | See table below | See table below |
Continuous Rating | See table below | See table below |
Auto releasing | Auto releasing | |
Operating Current: Continuous | <13mA@ 25°C nominal voltage | <13mA @ 25°C nominal voltage |
Changing Stage (20 ms) | <7A@ 25°C nominal voltage | <4A @ 25°C nominal voltage |
Contact Circuit Voltage | 16V DC Max. | 32V DC Max. |
Live Current Switching | 300A @ 12V | 150A @ 24V |
Mechanical Endurance | 100,000 Cycles | 100,000 Cycles |
Control Circuit Voltage | ||
Terminal Stud Size | ||
Maximum Terminal Stud Torque | 140 | 140 |
Ring Terminal Size | 3/8" (M10) | 3/8" (M10) |
Terminal Ring Diameter Clearance | 1.18" (30 mm) | 1.18" (30 mm) |
‡ Predicted performance |
|
|
Remote Switch PN 2155 |
|
|
Action | SPDT, |
|
Seals | Internal & External Gasket Panel Seal | |
Mounting Hole | 0.83"x 1.45" (21.08 mm x 36.83 mm) | |
LED Rating | 100,000 hours |
|
Harness Connector: (select models) | Deutsch DTM Series DTM |
|
Mating Part Requirements | See LADD Industries www.laddinc.com | |
Receptacle Shell |
| |
Wedgelock |
| |
Terminal Pins |
| |
Sealing Plugs |
| |
Hand Crimp Tooling |
|
Regulatory Meets ISO 8846 and SAE J1171 external ignition protection requirements, CE marked, Rated IP66
Wire Size (AWG) | Metric (mm²) | Cranking 10 sec. | Cranking 1 min. | Intermittent 5 min. | Continuous (UL 1107) |
|
|
|
|
|
|
2/0 | 70 | 2,000A | 750A | 400A | 225A |
4/0 | 120 | 2,200A | 750A | 400A | 300A |
2x (4/0) | 2x (120) | 2,500A | 1,100A | 700A | 500A |
PN | Termination | Control Circuit | Remote Control | |
Switch Included | ||||
|
|
| ||
|
|
|
| |
7712 | Tinned Wires | 12V DC | SPDT, | |
7712B | Tinned Wires | 12V DC | - | |
7712100B | Deutsch Connector | 12V DC | - | |
7714 | Tinned Wires | 24V DC | SPDT, | |
7714B | Tinned Wires | 24V DC | - | |
7714100B | Deutsch Connector | 24V DC | - |
Blue Sea Systems Inc. | p 360.738.8230 |
425 Sequoia Drive | f 360.734.4195 |
Bellingham, WA 98226 USA | conductor@bluesea.com |
980010060 Rev.004 | www.bluesea.com |
|
Overview of Application
The
Install a single pole double throw (SPDT) or single pole single throw (SPST) control switch in a convenient location near other electrical controls or companionway to allow quick access in the event of an emergency (see Illustration on reverse).*
*Although a SPST switch may be used if desired, use of a SPDT switch improves immunity to inadvertent switching if the controls become damp.
|
|
|
| ||||
Remote |
| ON |
|
|
|
| |
|
|
|
|
|
| ||
Switch |
| ON |
|
| OFF |
| |
State |
|
|
|
|
|
| |
|
|
|
|
| OFF |
| |
| Remote Operation Enabled | Remote | Remote Operation Enabled | Remote | |||
| Disabled | Disabled | |||||
Manual |
|
|
|
| |||
|
|
|
|
|
| ||
Control |
|
|
|
|
|
| |
Knob |
|
|
|
|
|
| |
Position |
|
|
|
|
|
| |
ON | OFF | OFF | ON | OFF | OFF | ||
Relay State | (Closed) | (Open) | (Open) | (Closed) | (Open) | (Open) | |
|
|
|
|
|
| ||
State will change |
| ON |
| OFF |
|
| |
to Remote | - | - | - | - | |||
(Closed) | (Open) | ||||||
Switch State |
|
|
|
| |||
|
|
|
|
|
| ||
after 10 minutes |
|
|
|
|
|
|
CAUTION If the
Remote LED Indicator embedded in PN 2155 SPDT ON-ON Contura Switch
indicates Remote Battery Switch state or condition as follows:
LED Indication | Remote Battery Switch State or Condition | |
LED is OFF | Remote Battery Switch is OFF | |
|
| |
LED is ON | Remote Battery Switch is ON | |
LED double blinking | Manual | |
OR Remote Battery Switch mechanical failure | ||
| ||
|
|
The remote LED embedded in PN 2155 indicates a closed connection between battery bank and load, or between two battery banks when used as an emergency
Remote Operation. PN 2155 (SPDT,
To connect battery bank to load, or combine | Set remote switch 2155 to position marked “ON”. |
battery banks | Remote LED indicates closed connection. |
|
|
To disconnect battery bank from load, or | Set remote switch 2155 to position marked “OFF”. |
isolate battery banks that are connected |
|
|
|