| D |
| C |
Outlet | Inlet |
| D | Auxiliary |
| C | Outlet |
Outlet | Inlet | T&P |
Auxiliary |
| Relief |
| Valve | |
Outlet: |
|
|
32EC/BCS, |
| B |
71EC, |
| |
51EC/BCS |
| Aquastat |
T&P |
| Connection |
|
|
C
Outlet
High Limit
T&P
Relief
Valve
B
Aquastat
Connection
Relief |
|
|
|
Valve |
|
| |
Aquastat |
| Return: |
|
Connection | B | A | |
| 120E, | ||
A | 190E, |
| |
71E | 241E, |
| |
| 361E |
| |
|
|
| |
50ES |
| Drain |
|
Drain |
| Valve/ |
|
Valve/ |
| Return |
|
Return: |
|
|
|
71E |
|
|
|
Drain |
|
|
|
Inlet/
Return
Drain
Valve
A
Valve/ | E | |
Return: | ||
| ||
32E, |
| |
50ES, 51E | E | |
71E | 72E, 73E, 120E, | |
| 190E, 241E, 361E |
E
541E
Model | Storage | Rated Input | Recovery | Max. Temp | Inlet | Outlet | Return |
| Dimensions |
| Shipping Weight | ||||
|
| @ ∆ 90°F | Setting | Pipe | Pipe | Pipe |
|
|
|
|
| (lbs)*** | |||
| (gal) |
|
| (GPH) | (°F) | Dia. | Dia. | Dia. |
|
|
|
|
|
|
|
| BTH/HR | GPH | A | B | C | D | E | Standard | ASME | ||||||
|
| ||||||||||||||
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71E | 68 | 173,000 | 1.25 | 177 | 160** | 1” | 1 1/2”* | 1 1/2” | 66” | 26” | 6” | 13 1/2” | 22” | 438 | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
72E | 67 | 199,000 | 1.50 | 212 | 160** | 1” | 1 1/2”* | 1 1/2” | 58” | 28” | 8” | 16” | N/A | 503 | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
73E | 67 | 242,000 | 1.75 | 258 | 180 | 1” | 1 1/2”* | 1 1/2” | 58” | 28” | 8” | 16” | N/A | 503 | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
120E | 113 | 155,000 | 1.10 | 163 | 180 | 1” | 2”* | 2” | 67” | 31 1/2” | 6” | 19” | 22” | 709 | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
190E | 113 | 190,000 | 1.35 | 199 | 180 | 1” | 2”* | 2” | 67” | 31 1/2” | 6” | 19” | 22” | 709 | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
241E | 109 | 277,000 | 2.00 | 286 | 180 | 1” | 2”* | 2”* | 67” | 31 1/2” | 8” | 19” | 22” | 856 | 912 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
361E | 91 | 415,000 | 3.00 | 443 | 180 | 1” | 2”* | 2”* | 67” | 31 1/2” | 9” | 23” | 26” | 1014 | 1050 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
541E | 83 | 623000 | 4.5 | 648 | 180 | 2” | 2”* | 2”* | 66” | 34” | 10” | N/A | 30 1/2” | 1232 | 1258 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Nipple not included
**Optional setting, contact factory
***Weight does not include burner and controls
T&P Valve: Factory Installed | (on selected models) |
| |
Drain Valve: Factory Installed Brass Valve |
|
Standard Voltage (all): 120V, 60 Hz, 1P |
|
Pressures (all): Working Pressure, 150 psi; Testing Pressure, 300 psi |
|
ASHRAE: All Bock Products Meet or Exceed Current ASHRAE Standards. |
|
Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 31 or ANSI Z.21.10.1.
Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or