Quick Troubleshooting Check List

Quick Troubleshooting Check List

If you experience a problem during the normal operation of the T280P – T280C – T320, use the following troubleshooting table below. If you are unfamiliar or uncertain with basic diagnostic maintenance procedures, contact your Authorized Bodyguard® Dealer for diagnostics or repair of your T280P – T280C – T320.

Table 3

PROBLEM

POSSIBLE CAUSE/SOLUTION

• Computer will not light

• Unit is not plugged in. – Plug unit in.

up when power

• Power cord. – Check that power cord is functional; replace if necessary.

is turned ON.

• Circuit breaker. – Reset the breaker.

 

 

• Damaged motor circuit board. – Contact your Bodyguard® Dealer.

 

• The belt is over tensioned. – Perform Belt Alignment.

 

• The wires are not connected. – Remove the cover and connect the wires properly.

 

 

• Belt doesn’t turn.

• Magnetic key is not in place. – Insert the magnetic key.

 

 

• Elevation does not

• It is not calibrated. – Perform Elevation Calibration.

respond properly.

• The wire is not connected on the motor circuit board. –

 

 

Connect the elevation wire to the circuit board.

 

 

• Motor drive does not

• It is not calibrated. – Perform Motor Check.

respond properly.

• The wire is not connected on the motor circuit board. –

 

 

Motor wiring harness needs to be connected to the lower board.

 

 

• Motor turns backwards.

• The wires are reversed on the circuit drive. –

 

Contact your Bodyguard® Dealer.

• Computer key(s) not

• Keypad may be damaged by liquid penetrating through the seal. –

responding to touch,

Contact your Bodyguard® Dealer.

or sticking.

• Excessive amount of cleaning solution used. –

 

Use mild cleanser on damp cloth only when cleaning console and unit.

 

 

• Squeaking noise from

• Poly V-belt slipping. – Contact your Bodyguard® Dealer.

the motor.

• Motor brush noise excessive. – Contact your Bodyguard® Dealer.

• Belt tracks left

• Uneven floor. – Move the treadmill to an even floor.

and right.

• Rear roller not adjusted for sloped floor. –

 

The rear roller needs to be adjusted. Perform Belt Alignment.

 

 

• Speed is not constant or

• The drive motor is not calibrated. – Perform Motor Check.

seems too fast or slow.

• The tension on the motor drive is too excessive. –

 

Remove tension on the running belt. Perform Belt Alignment.

 

 

• Can’t get out at the end

• Elevation is not calibrated. – Perform Elevation Calibration.

of a program.

 

 

 

• Error log

• See table 4

 

 

30