Manual Sections Affected:

PCM2000 ADDENDUM

The PCMTIM module has a feature that was not listed separately in its User’s Manual.

Manual Sections Affected:

Section 1 — PBX Loop Start Trunk Port , PBX Ground Start Trunk Port

Feature:

Trunk Disconnect

Purpose:

Allows the PCM2000 to issue a one-second disconnect signal (loss of loop cur- rent) after its default time or VOX time has elapsed.This applies only to Loop Start and Ground Start applications and is defeatable.The disconnect signal can allow compatible equipment to clear the paging line should a paging phone be

improperly hung up.

New Feature Codes:

FEATURE

FEATURE CODE

ADDITIONAL DATA DEFAULT CONDITION

Trunk Disconnect

014

Inhibit

Inhibit

 

015

Enable

 