25V & 70V Connection
You can connect a 25 or 70V balanced or unbalanced line to the terminals marked 25V or 70V and GND. 25V line connec- tion is shown below.
Speaker Zone Connection
You can connect up to 4 separate speaker zones.
To connect zones of 4 - 8Ω speakers: Connect the imped- ance selector jumper wire to the
shorting bar between the LINK terminals. Connect one 8- ohm speaker to the desired zone terminal and COM, as shown below.
Connect only
one
For more than
one speaker per zone, use 25V or 70V speakers.
Impedance selector wire from back of unit.