Bogen V250, V60 Troubleshooting, Ensure that all AC safety grounds are connected, the same ground

Models: V250 V100 V150 V60

1 16
Download 16 pages 61.85 Kb
Page 15
Image 15
Troubleshooting

Troubleshooting

PROBLEM

CONDITION

CAUSE

 

 

• Amplifier not plugged in.

 

Power Indicator LED is off.

• AC outlet dead.

 

• Power switch off.

 

 

 

 

• Circuit breaker tripped.

 

 

 

 

Power Indicator LED is red.

• No signal from source.

 

Input Signal / Clip LED is off.

• Module not installed correctly.

NO SOUND

 

 

Power Indicator LED is red.

• Master or input channel volume control turned down.

 

 

Input Signal / Clip LED is green.

• Insert loop is “broken.” (RCA Plug in Sig Proc IN

 

LED Output Meter is off.

connector)

 

 

 

 

Power Indicator LED is red.

• Speaker connections on amplifier incorrect.

 

• Trans / Direct Out selector not set correctly.

 

Input Signal / Clip LED is green.

 

• Poor / broken speaker wiring.

 

LED Output Meter is operating.

 

• Defective speakers.

 

 

 

Power Indicator LED is red.

 

 

Input Signal / Clip LED is green.

• Partial short on the output.

 

Volume Controls are turned up and

 

shows little activity.

 

 

Unit is extremely hot.

 

 

 

 

 

Power Indicator LED is red.

• Signal from source is already distorted.

 

• Poor speaker connections.

 

Input Signal / Clip LED is green.

 

Trans-Out load on wrong tap.

DISTORTED

LED Output Meter is not in red.

• Bass control boosted too much.

SOUND

 

 

 

 

 

 

 

Power Indicator LED is red.

• Input signal level to module too high (should cause red

 

LED).

 

Input Signal / Clip LED is red.

 

• Input module gain too high (if available).

 

LED Output Meter is not in red.

 

• Input module being overdriven by a high input signal.

 

 

 

 

 

 

Power Indicator LED is red.

• Input volume controls set too high.

 

Input Signal / Clip LED is green.

 

• Input master volume control set too high.

 

LED Output Meter in red.

 

 

 

 

 

 

 

Lo-cut switch is set to ON.

POOR

Power Indicator LED is red.

• Speakers wired out of phase.

LOW FREQ.

• Check module bass control setting (if available).

Input / Signal Clip LED is green.

RESPONSE

• Check bass control setting.

LED Output Meter not in red.

(NO BASS)

• Note: Transformer-coupled speakers have less bass

 

 

 

response.

 

 

 

 

 

• Poor electrical connections at input.

 

 

• Input cable routed near AC cables, power transformer, or

 

 

other EMI radiating devices.

 

Power Indicator LED is red.

• Electrically noisy devices operating on the same AC

NOISE/HUM

Volume controls are in normal

circuit.

 

operational position.

• Poor equipment grounding.

 

 

- Ensure that all AC safety grounds are connected.

 

 

- Make sure that all components in audio chain are tied to

 

 

the same ground.

 

 

 

 

 

13

Page 15
Image 15
Bogen V250, V60, V150, V100 specifications Troubleshooting, Ensure that all AC safety grounds are connected, the same ground