WATER CONNECTIONS

When facing the heater, the cold water inlet is on your right and the hot water outlet is on your left.

Although water piping throughout your structure may be other than copper, we recommend that copper piping be used for at least three feet before and after the heater (follow local codes if more stringent). Keep water inlet pipe to no less than 1/2 inch diameter to allow the full flow capacity. Remember that water pressure must be sufficient to activate the heater when drawing hot water from the top floor. If the hot and cold connections to the heater are reversed, the heater will not function. The AquaStar 125HX is provided with one flexible type connector that must be connected to the inlet fitting of the water valve as shown in Fig 5. ½” Copper or brass fittings work best when connected to the connectors. See Fig 6. The flexible type connector seals to the water valve by means of a union connection with a washer type gasket at the joint. No pipe dope or thread tape is to be used at this joint.

This fitting seal to the water valve by means of a union connection with a washer type gasket at the joint. No pipe dope or thread tape is to be used at these joints. Be certain there are no loose particles or dirt in the piping. Blow out or flush the lines before connecting to the AquaStar. Full port valves should be installed on both the cold water feed line and the hot water outlet line to facilitate servicing the heater. For installation on a private well system, be sure that the water pressure is set between 30 and 50 psi.

Fig. 5 - Water valve - top view

THREADEDASSEMBLY SWEATED ASSEMBLY

1/2” FLEX

1/2” FLEX

PIPE PRV TO

PIPE PRV TO

APPROPRIATE

APPROPRIATE

DISCHARGE

DISCHARGE

 

Fig. 6 - Plumbing connections for the Aquastar

125HX

Connecting the pressure relief valve (PRV)

A listed pressure relief valve supplied with the heater must be installed at the time of installation. No valve is to be placed between the PRV and the heater. No reducing coupling or other restriction may be installed in the discharge line.

The discharge line must be installed such that it allows complete drainage of both the PRV and the line.

The location of the PRV must be readily accessible for servicing or replacement, and be mounted as close to the water heater as possible. See Fig 7. To install the PRV, a suitable fitting connected to an extension on a “T” fitting can be sweated to the hot water line.

Support all piping.

Fig. 7 - Pressure Relief Valve

OPERATING INSTRUCTIONS

Before proceeding with the operation of the heater make sure that the system is filled with water.

Open the cold water inlet supply to the heater fully. Open a hot water faucet to permit the water to fill the heater and the piping and to eliminate the air trapped in the system Close the hot water faucet after the water flows freely and all the air has escaped from the system. The water heater is now ready to operate.

FOR YOUR SAFETY READ BEFORE OPERATING YOUR HOT WATER HEATER

Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with electronic ignition for lighting the pilot and main burners. When turning the heater on, follow these instructions exactly.

B.Before operating the unit, set the On/Off switch to the

On ( ) position. The On/Off switch is located behind the flip-down coverplate on the front panel strip. Smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS - Do not try to light any appliance.

- Do not touch any electric switch; do not use any phone in your building

- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

- If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in the on/off control button. Never use tools. Follow these instructions exactly. If control button is jammed, close the gas supply and call a qualified service technician. Attempted forceful repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

6 720 606 804 (02.10)

9

Page 9
Image 9
Bosch Appliances 125HX NG specifications Water Connections, For Your Safety Read Before Operating Your HOT Water Heater

125HX NG specifications

Bosch Appliances has long been synonymous with innovation and quality, and their 125HX NG model is no exception. Designed for home cooks and culinary enthusiasts alike, the Bosch 125HX NG is a natural gas cooktop that combines state-of-the-art features with unmatched performance.

One of the standout features of the Bosch 125HX NG is its five powerful burners, which offer flexibility for various cooking techniques. These burners include a high-heat burner perfect for searing meats and achieving high-temperature cooking, along with a simmer burner designed for those delicate sauces and slow cooking tasks. The configuration of the burners allows for multiple pots and pans to be used simultaneously, maximizing efficiency and convenience in the kitchen.

The surface of the cooktop is constructed from premium stainless steel, offering not only a sleek aesthetic but also durability that withstands the rigors of daily cooking. The seamless design facilitates easy cleaning, ensuring that spills and stains can be wiped away with minimal effort.

Technology plays a key role in the Bosch 125HX NG model, featuring precise temperature control and rapid ignition systems. The automatic re-ignition feature enhances safety, ensuring that the flame is reignited if it goes out unexpectedly, providing peace of mind to users while cooking.

Another notable characteristic is the cooktop’s continuous grates, which provide stability for pots and pans, allowing for effortless sliding between burners without the risk of spills. These heavy-duty grates contribute to the overall robustness of the cooktop, reinforcing Bosch’s commitment to functional design.

In terms of installation, the Bosch 125HX NG is compatible with various kitchen layouts, making it a versatile choice for both new builds and remodels. The model is also designed with energy efficiency in mind, helping homeowners to save on gas consumption while enjoying consistent cooking results.

Overall, the Bosch Appliances 125HX NG is a sophisticated and reliable natural gas cooktop that caters to the needs of modern cooking. With its array of features, advanced technologies, and high-quality materials, it's a perfect addition to any kitchen, appealing to both amateur cooks and seasoned chefs. Investing in a Bosch 125HX NG means enjoying durability, functionality, and style in one exceptional cooking appliance.