1.STOP! Read the safety information above on this label.

2.The gas valve must be shut off by putting the ON/OFF

switch to position “ TO TURN OFF GAS TO APPLIANCE ”. Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.

3.This water heater is equipped with a safety pilot burner and an automatic ignition control system.

4.Set the ON/OFF switch (flip down cover plate on front

panel strip) to the SETTING THE WATER TEMPERATUREposition. In this position, the water heater is ready to use.

5.If the red LED indicator light is flashing, this is a warning that the water pressure is not enough to ignite the main burner.

6.Turn the hot water faucet on to the minimum flow rate required to activate the heater. The automatic ignition system first ignites the safety pilot burner which then ignites the main burner in about 4 seconds.

7.The green LED indicator is on when the main burner is on.

8.The pilot flame will extinguish 10-30 seconds after the burners come on. The burners will remain on until the hot water tap is turned off.

NOTE: On a first time initial installation, existence of air in the gas supply line and in the water line may cause some ignition delay. In that case, repeatedly open and close the hot water tap in order to restart the ignition process until all the air has been purged.

TO TURN OFF GAS TO APPLIANCE

Turn off the manual lever on the gas supply line to the

heater and set the ON/OFF switch to the OFF ( Fig. 8 - Temperature Adjustment Knob ) position. See Fig 9.

SETTING THE WATER TEMPERATURE

The AquaStar 125 HX LP and 125 HX NG water heaters have a gas control that modulates burner input in response to flow. Its purpose is to ensure that the hot water temperature will remain steady, although the water flow demand might vary (down to 1/2 gal/minute). To adjust the temperature on your AquaStar, turn on a hot water faucet to its maximum flow. At the water heater, turn the large knob located beneath the main gas control on the front of the heater all the way to the right (clockwise). See Fig 8. This will produce a temperature rise of approximately 90°F at flow rates between 0.5 and 2.0 gallons per minute. Given that average incoming water temperatures are 50°F, this heater will produce approximately 140°F water at these flow rates. Turning the dial all the way to the left (counterclockwise) will produce a temperature rise of approximately 45°F for flow rates between 1.1 and 3.7 gallons per minute. It is safest to select a comfortable temperature and not have to mix in cold water.

Fig. 8 - Temperature Adjustment Knob

The position you select on the temperature adjustment knob will depend on the temperature of the incoming water (50°F is average in the U.S.). In warm weather regions where the incoming cold water is generally warmer, or during the hot weather months in some other areas a midway setting on the temperature adjustment knob would produce a temperature rise of about 70°F, giving an output of approximately 120°F. At this setting, if it is still necessary, one could mix a small amount of cold water in a shower and have a comfortable shower at about 3 gallons/minute. During the colder months, or in cold climate areas, it might be necessary to set the control to the maximum position, all the way clockwise to the right.

If you supply the AquaStar 125HX, with preheated water (i.e.) in a solar installation the unit could overheat. It will then shut off on safety when the outlet temperature reaches 194°F. For this type of application, purchase a solar model 125B LPS or 125B NGS.

To start and to shut down the appliance press the button “ - on”.

The switch is located behind the flip down cover plate on the front panel strip.

Fig. 9 - Principles of OperationManual background - on

- off

Green light on = main burner on.

Green light off = main burner off.

If the red light is flashing, that means the water flow is not enough to ignite the burner.

Temperature Adjustment Knob

Decrease

Increases temperature

temperature and

and decreases flow

increase flow

G661_004

 

Fig. 9 - Principles of Operation

10

6 720 606 804 (02.10)

Page 10
Image 10
Bosch Appliances 125HX NG Lighting And Operating Instructions, Setting The Water Temperature, To Turn Off Gas To Appliance