Special adjustment for measuring and adjusting CO2 levels

D. Returning to Service:

1.Return slotted cover to original position.

2.Reinstall Torx cover.

3.Remove CO2 analyzer probe and reinstall flathead screw in exhaust collar.

4. Turn ON/OFF switch to the OFF (O) position and then back to the ON (I) position.

5. Heater is ready for normal operation.

 

 

Without Front

With Front

 

 

 

 

Cover

Cover

 

 

 

Nat. Gas

Nat. Gas

 

max. input

P1

9.1 ± 0.1 %

9.7 ± 0.1 %

 

min. input

P2

9.4 ± 0.1 %

9.7 ± 0.1 %

 

 

 

 

LP Gas

LP Gas

 

max. input

P1

10.1 ± 0.1 %

10.7 ± 0.1 %

Fig. 45

 

min. input

P2

10.4 ± 0.1 %

10.7 ± 0.1 %

 

* Final reading must be confirmed with the front cover

 

on, CO2 levels increase when the cover is installed.

 

Table 9

 

 

 

 

 

 

Final Readings

 

 

 

 

 

P2 CO2 Reading:

 

 

% CO2

 

 

 

 

P1 CO2 Reading:

 

 

% CO2

 

 

 

 

 

 

 

Fig. 44

6 720 608 263

33