Special adjustment for measuring and adjusting CO2 levels
D. Returning to Service:1.Return slotted cover to original position.
2.Reinstall Torx cover.
3.Remove CO2 analyzer probe and reinstall flathead screw in exhaust collar.
4. Turn ON/OFF switch to the OFF (O) position and then back to the ON (I) position.
5. Heater is ready for normal operation.
|
| Without Front | With Front |
| ||
|
|
| Cover | Cover |
| |
|
| Nat. Gas | Nat. Gas |
| ||
max. input | P1 | 9.1 ± 0.1 % | 9.7 ± 0.1 % |
| ||
min. input | P2 | 9.4 ± 0.1 % | 9.7 ± 0.1 % |
| ||
|
|
| LP Gas | LP Gas |
| |
max. input | P1 | 10.1 ± 0.1 % | 10.7 ± 0.1 % | Fig. 45 | ||
| ||||||
min. input | P2 | 10.4 ± 0.1 % | 10.7 ± 0.1 % |
| ||
* Final reading must be confirmed with the front cover |
| |||||
on, CO2 levels increase when the cover is installed. |
| |||||
Table 9 |
|
|
|
|
|
|
Final Readings |
|
|
|
|
| |
P2 CO2 Reading: |
|
| % CO2 |
| ||
|
|
| ||||
P1 CO2 Reading: |
|
| % CO2 |
| ||
|
|
| ||||
|
|
|
Fig. 44
6 720 608 263 | 33 |