Bosch Appliances DAH93 Connect Wiring, Accessories, Reassemble Hood, For Internal Blower Use

Models: DAH93 DAH94, DAH95

1 6
Download 6 pages 15.29 Kb
Page 5
Image 5
6. Connect Wiring

Installation

6. Connect Wiring

For Internal Blower Use: WARNING:

Use only spring type wire nuts (included) to make electrical connections. Replacement wire nuts must be rated for a minimum of (2) #18ga wires and a maximum of 4 #14ga wires, UL & CSA rated to 600V and 302º F/ 150º C. Request #189692 when ordering from

BSH.

For Internal Blower Use:

See Figure 1 or 2, page 3.

1.Remove electrical knockout behind J box and install 1/2” conduit connectors.

2.Run 120V AC 60Hz, 15A supply wires through 1/2” conduit to hood electrical knockout behind J box cover.

3.Connect blower cord wires to house wiring through electrical knockouts. Use wire nuts supplied (white to white, black to black, green to green).

4.Connect blower cord at white connector behind connector access panel (if not already connected). Verify that connectors are tightly connected.

For Remote Blower Use:

See Figure 3, page 3.

1.

Remove 2 hood electrical knockouts and install

 

1/2” conduit connectors.

2.

Run black, white and green supply wires through

 

1/2” conduit to hood electrical knockout behind

 

J box.

3.

Connect power supply wires to hood wires behind

 

J box (white to white, black to black, green to

Accessories

The following accessories are available from your Bosch dealer or through Bosch Service: 800-944-2904. Please reference the model number when requesting these items.

Accessory

Model #

6” Duct Covers

30”

36”

Biscuit

DCZ7607UC

N/A

Black

DCZ7606UC

DCZ9666UC

Stainless Steel

DCZ7605UC

DCZ9665UC

White

DCZ7602UC

DCZ9662UC

12” Duct Covers

30”

36”

Biscuit

DCZ7207UC

N/A

Black

DCZ7206UC

DCZ9266UC

Stainless Steel

DCZ7205UC

DCZ9265UC

White

DCZ7202UC

DCZ9262UC

Recirculation Kit

30”

36”

Biscuit

DRZ7007UC

N/A

Black

DRZ7006UC

DRZ9066UC

Stainless Steel

DRZ7005UC

DRZ9065UC

White

DRZ7002UC

DRZ9062UC

Charcoal Filter

DHZ7960UC

3 1/4 x 10Transition

DHZ3410UC

Blowers*

 

 

Integral Blower, 400 CFM

DHG4001UC

Integral Blower, 600 CFM

DHG6001UC

Remote Blower, 600 CFM

DHG6003UC

Remote Blower, 1000 CFM

DHG1003UC

*for use with DAH95 models only

 

 

Figure 6 - Remote Blower Pigtail Assembly

green). Use wire nuts supplied.

4. Run 5 wires (#14 AWG) in 1/2” conduit from the

remote blower to the electrical knockout behind

the remote wire cover.

N GND L1

( PROVIDED W/HOOD )

5.

Connect remote blower wiring to “pigtail” wires

 

behind remote wire cover with wire nuts supplied

 

(white to white, black to black, green to green and

 

black to brown, white to white, red to red and

 

blue to blue) See Figure 6.

6.

Connect other end of “pigtail” at white connector.

 

Verify that connectors are tightly connected.

7. Reassemble Hood

Reattach the following:

1.Connector access panel (internal blower only)

2.J box

3.Remote wire cover (remote blower use only)

4.Back filter rail

5.Filters

 

BLACK

 

 

 

WHITE

BROWN

BLUE

 

 

 

BROWN

 

RED

 

 

 

M

WHITE

 

 

RED

 

 

 

 

 

 

BLUE

 

 

GND

 

 

 

5

Page 5
Image 5
Bosch Appliances DAH93 Connect Wiring, Accessories, Reassemble Hood, For Internal Blower Use, For Remote Blower Use