The use of a Sonalert type device (sounder) will provide an audible tone during the time the unit is in alarm. Of the three available connec- tor pins, the center pin is positive (+) with respect to either outside pin (outside pins are common
CAUTION!
Be sure all wiring is unpowered
Use of the sounder is intended only as an aid for walk testing during installation.
3. Place the cover on the unit, and
NOTICE!
Be sure the TC6000 and Sonalert leads are dressed through the cut- out.
4.Apply power to the unit.
5.Wait at least two minutes, after applying power, to start walk tests.
NOTICE!
Walk testing should be done across the coverage pattern as shown.
REAR WIRE | TERMINAL |
ENTRANCE | STRIP |
| 1 |
WIRE | 8 |
| |
MOUNTING | INTERFACE |
SLOTS (4) | PINS |
Mounting Base
Figure 2.3: Overview
REQUIRED FOR EN50131
INST ALLA TIONS
| TEST LEAD SOUNDER | ALARM/TEST LED |
| INDICATOR (3) | |
| CUTOUT |
|
| NOISE |
|
| VOLTAGE |
|
| LO |
|
| HI |
|
| ON |
|
| OFF |
|
GAIN SELECT |
| |
JUMPER |
| |
LO |
| COVER |
|
| |
HI | CONFIGURATION | TAMPER |
| ||
| SWITCHES |
|
|
| |
| REQUIRED FOR EN50131 |
|
| INSTALLATIONS |
|
| Top View of Enclosure | |
| with Cover and Optical Module Removed |
6.The edge of the coverage pattern is determined when the Alarm/Test LED indicator (and optional Sonalert®, if installed) first turns on.
7.Walk test the unit from all directions to determine the boundaries.
8.After completion of the walk tests, remove the Sonalert® (if installed).
6 Final Tests
6.1 Noise Measurement
NOTICE!
Meter readings are very important in determining background distur- bance levels and catch margin sensitivity.
1.Connect a 20,000 ohm/volt (or greater) DC VOM to the Noise Voltage connector using the TC6000 as shown. Set meter scale for about 3.0 VDC.
2.The base reference level for reading background noise or target volt- ages is approximately 2.0 VDC. Installations in quiet environments, therefore, will result in a steady meter reading between 1.9 and 2.1 VDC. Look for areas and sources of thermal disturbances if the meter fluctuates greatly.
4.Firmly mount the base. Depending on local regulations, the base may be directly surface mounted using anchors, mollies, or
NOTICE!
The DS938Z base will not completely cover a
NOTICE!
Mounting to removable ceiling tiles is not recommended unless a sandwich is made of the base, ceiling tile, and a back plate behind the tile. Covers used for
3 Wiring
CAUTION!
Only apply power after all connections have been made and inspected. Do not coil excess wiring inside detector. Use no smaller than #22 AWG (0.8 mm) wire in the terminal strip.
8 © 2012 Bosch Security Systems, Inc. | F.01U.263.663 01 05.2012 5 |