DX4010i Installation Instructions 4.0 Wiring
4.0 Wiring
Remove all power to the control panel (AC and standby battery) before making or breaking any connections. Failure to do so can result in personal injury or damage to the equipment.
Wire Length Restrictions
•0.8 mm (#22 AWG): 305 m (1000 ft)
•1.2 mm (#18 AWG): 610 m (2000 ft)
SDI wiring is limited to 305 m (1000 ft).
Connect the DX4010i to the control panel data and auxiliary power sources as shown in Figure 2.
Figure 2: Control Panel Connections
1 | 2 |
B | 3 |
G | 4 |
Y | 5 |
R | 6 |
Figure 3: External Power Supply Connections
1 | 2 |
| 3 |
| 4 |
| 5 |
| 6 |
+ | - |
| 7 |
1- DX4010i data bus
2- Control panel data bus
3- Option AUX common/SDI common (black)
4- Option data/SDI B (green)
5- Option data/SDI A (yellow)
6- Option AUX power +/SDI power (red)
7- External 12 VDC power supply
Figure 4 shows serial
Figure 4: Serial Device Connections
1- DX4010i data bus
2- Control panel data bus
3- Option AUX common/SDI common (black)
4- Option data/SDI B (green)
5- Option data/SDI A (yellow)
6- Option AUX power +/SDI power (red)
If an external 12 VDC power supply is used, wire as shown in Figure 3.
|
|
|
|
|
|
|
|
|
|
|
|
Rx Tx | Tx Rx | ||||
BUS |
| SER |
P3
LED |
ENABLE |
P2 |
P6 |
P1 |
DB9 GND |
ENABLE |
1
1- Serial
See Section 7.0 DB9 DTE
Figure 5 shows a parallel printer connected to the serial output of the DX4010i. This type of connection requires the use of a serial to parallel converter, such as the BlackBox PI045A serial to Centronics parallel converter cable. The cable is available from BlackBox® (www.blackbox.com).
Bosch Security Systems, Inc. 1/05 4998141106C | 5 |