DX4010i Installation Instructions 6.0 Remote Programming Direct Connection
Table 4: SDI Bus Address DIP Switch Settings
|
|
|
|
|
|
|
|
|
|
|
|
|
| SDI DIP Switch Settings |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
SDI DIP | S1 | S2 | S3 | S4 | S5 |
| S6 | S7 | S8 |
Switches |
|
|
|
|
|
|
|
|
|
Module | 1 | 2 | 4 | 8 | 16 |
| 32 | 64 | 128 |
Address |
|
|
|
|
|
| (Mode) | (Option/SDI) | (Checksum +1) |
80* | ON | ON | ON | ON | OFF |
| OFF | OFF | OFF |
81 | OFF | ON | ON | ON | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
82 | ON | OFF | ON | ON | OFF |
| OFF | OFF | OFF |
83 | OFF | OFF | ON | ON | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
84 | ON | ON | OFF | ON | OFF |
| OFF | OFF | OFF |
85 | OFF | ON | OFF | ON | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
86 | ON | OFF | OFF | ON | OFF |
| OFF | OFF | OFF |
87 | OFF | OFF | OFF | ON | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
88** | ON | ON | ON | OFF | OFF |
| OFF | OFF | OFF |
89 | OFF | ON | ON | OFF | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
8A | ON | OFF | ON | OFF | OFF |
| OFF | OFF | OFF |
8B | OFF | OFF | ON | OFF | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
8C | ON | ON | OFF | OFF | OFF |
| OFF | OFF | OFF |
8D | OFF | ON | OFF | OFF | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
8E | ON | OFF | OFF | OFF | OFF |
| OFF | OFF | OFF |
8F | OFF | OFF | OFF | OFF | OFF |
| OFF | OFF | OFF |
|
|
|
|
|
|
|
|
|
|
Positions 5, 6, and 8 are not used for SDI bus.
* Used for BIS, PC 9000, and other third party applications. ** Used for RPS and alternate communication.
SDI bus control panels (v6.0 or higher): D9412G, D7412G, D7212G, D9124, D9112, D7412, and D7212.
Bosch Security Systems, Inc. 1/05 4998141106C | 9 |