Operation
Initial Operation
•Protect the tool against moisture and direct sun irradiation.
•Do not subject the tool to extreme temperatures or variations in temperature.
As an example, do not leave it in vehicles for longer periods. In case of large variations in temperature, allow the
tool to adjust to the ambient temperature before putting it into operation. In case of extreme temperatures or variations in temperature, the accuracy of the tool can be impaired.
•Avoid heavy impact or falling of the tool. After heavy exterior impact on the tool, an accuracy check should always be carried out before continuing to work (see “Leveling Accuracy”).
•Switch the tool off during transport. When switching off, the leveling unit, which can be damaged in case of intense movement, is locked.
Switching On and Off
To switch on the tool, push the On/Off switch 7 to the “ on” position (when working without automatic leveling) or to the “ on” position (when working with automatic leveling). Immediately after switching on, the tool sends laser beams out of the exit openings 1.
•Do not point the laser beam at persons or animals and do not look into the laser beam yourself, not even from a large distance.
To switch off the tool, push the On/Off
switch 7 to the “off” position. When switching off, the leveling unit is locked.
Deactivating the Automatic
•Do not leave the switched on measuring tool unattended and switch the
tool off after use. Other persons could be blinded by the laser beam.
To activate the automatic
operating mode button 4 pushed).
Operating Modes (see figures A–D)
The tool has three operating modes between which you can switch at any time:
–Horizontal operation
–Vertical operation “l”: Produces a vertical laser line,
–
All three operating modes can be selected in the automatic leveling mode. In the locked mode, either the horizontal operation or the vertical operation mode can be selected.
After switching on, the tool is in
Pulse Function
The LR2 laser receiver allows the
In pulse function, the laser lines flash at very high frequency and thus become detectable for the laser receiver 16.
To switch on the pulse function, press button 3. When the pulse function is switched on, the
When the pulse function is switched on, the visibility of the laser lines is reduced for the human eye. Therefore, shut off the pulse function by pushing button 3 again when working without laser receiver. When the pulse function is switched off, the pulse- function indicator 2 is deactivated.
Automatic Leveling
Working with Automatic Leveling (see figure C)
Position the tool on a level and firm support or attach it to a commercially available photographic tripod.
When working with automatic leveling, push the On/Off switch 7 to the “ on” position.
After switching on, the leveling function automatically compensates irregularities within the