LTC9316/00P
Table of Contents
1DESCRIPTION
2UNPACKING
3SERVICE
44 INSTALLATION
4.1Site Preparation
4.2.Installation
4.3Mounting the AutoDome™
Instruction Manual Introduction
EN 2
2
2
2
3
3
3
4
1 DESCRIPTION
The LTC 9316/00P units are 16 foot steel mounting poles for use with Unity® Domes, AutoDomes®, and the LTC 9320 Series of Outdoor Fixed Domes.
2 UNPACKING
Unpack carefully. This is mechanical equipment and should be handled with care.
Check for the following:
•Packet Assembly for LTC 9316/00P:
1Bosch Adapter Plate.
43/8 x
4
45/16 Stainless Steel Flat Wash.
43/8 Stainless Steel Split Lockwasher.
45/16 Stainless Steel Split Lockwasher.
1Wiring grommet
1Conduit plug
1Installation Instructions (This Manual).
•Steel Pole
If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. If any items are missing, notify your Bosch Security Systems Sales Representative or
Customer Service.
The shipping carton is the safest container in which the unit may be transported. Save it for possible future use.
4 INSTALLATION
This installation should be made by qualified service personnel and conform to the National Electrical Code and applicable local codes.
! Please read these instructions carefully before proceeding, and heed all cautions.
4.1Site Preparation
NOTE: Special attention must be paid to the size of the
! wiring conduit and its location within the concrete foundation and jig (if applicable). The Wiring Conduit can be up to 2" in diameter. Use reducers if necessary. Also, make sure that the Wiring Conduit is in the center of the foundation and Anchor Jig during installation (Figure 1).
Mounting
Bolts
Up to | Wiring |
in Diameter | Conduit |
Figure 1 Mounting Bolts & Wiring Conduit Location
3 SERVICE
If the unit ever needs repair service, the customer should contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions.
Service Centers
U.S.A.: Phone:
Canada:
Europe, Middle East & Asia Pacific Regions:
For additional information, see www.boschsecuritysystems.com
1.Select a suitable site for the LTC 9316/00P and prepare the pad site using a hole 36" x 36" x 36" deep. The top of the concrete foundation should be flush with the ground.
CAUTION: Be sure that there are no underground electric or
!phone cables or gas or water lines in the area where the pole will be located.
2.To help reinforce the concrete foundation, place (12) 1/2" diameter
x32" long Reinforcement Bars (rebar) as shown in Figure 2. Use suitable preparation methods to place the rebar.
Bosch Security Systems 10 October 2003