LTC 8569 Series Instruction Manual Operation | EN 10 |
|
|
WARNING:
•Removal of the cover should only be performed by qualified service personnel.
The unit should always be disconnected from the mains power source before removing the cover, and remain disconnected while the cover is removed.
•
•The top cover is fastened to the case by four
(4) screws located on the rear of the unit. Remove these screws as shown in Figure 1.
•After the screws have been removed, the cover slides back and off the unit.
Figure 1 - Cover and Rack Brackets Removal
•Locate dip switch # S101, as shown in Figure 2.
Front Panel |
ON |
Dip Switch S101 |
Main board |
Rear Panel board |
Figure 2 - Dip Switch Location
•Make the desired changes per the table below:
S101 Dip Switch | Switch OFF | Switch ON |
2 | No change | Data received by Input |
| 2 offset by 16 |
|
3 | No change | Data received by Input |
| 3 offset by 32 |
|
4 | No change | Data received by Input |
| 4 offset by 48 |
|
•All other switches should be left in the OFF position.
•Reverse the procedure to reinstall the cover.
6OPERATION
When AC power is applied to the Code Merger, the front panel POWER LED illuminates. When biphase code is received at any of its inputs, the signal is reconstituted and distributed from all of its outputs. The CODE LED on the front panel will flash as output data is being produced.
Bosch Security Systems 15 March 2004