Installation Instructions
for the MX938i
Ceiling Mount Multiplex
PIR Intrusion Detector
1.0Specifications
•Input Power: Connects directly to the Multiplex Bus of the Control Panel and optionally to an auxiliary 12 VDC source.
•Current Draw:
LED Off:< 350 µA draw on Mux Bus.
In Alarm; LED On: 2 mA draw on Mux Bus.
LED Off:< 350 µA draw on Mux Bus.; 0 mA draw on Aux. power.
2.0Control Panel Programming
Refer to the multiplex programming section of your Control Panel Reference Guide for information on programming multiplex zones for this device.
3.0Mounting
Avoid
Moving objects | Moisture | |
| ||
| Mounting Outdoors | |
Hot or cold air | Direct or | |
reflected | ||
directed onto | ||
sunlight | ||
sensor | ||
| ||
| Pets or animals |
In Alarm; LED On: < 350 µA draw on Mux Bus; 3 mA draw on Aux. power.
• Standby Power: | There is no internal standby battery. Connect |
| to DC power sources capable of supplying |
| standby power if primary power fails. For each |
| hour of standby time needed, 350 µAh are |
| required. For UL Listed Requirements, four |
| hours (1400 µAh) minimum are required. |
• Coverage: | 360° by 60 ft. (18.3 m) diameter coverage |
| when mounted on 8 to 18 ft. (2.4 to 5.5 m) |
| high ceilings. Pattern consists of 64 zones |
Rear Wire | Terminal |
Entrance | Strip |
Wire
Pins
Mounting
Slots (4)
Module Tabs (2)
Sensitivity
Jumper
Signal
Gain
Jumper
LED
Operation
Jumper
Walk Test/Alarm
LED Indicator (3)
Terminal
Strip
Optical Module with Cutaway to show Circuit Board detail
|
| grouped into 16 barriers, with one additional |
|
| zone looking straight down from the unit |
|
| (sabotage). Each barrier is 30 ft. (9.2 m) long |
|
| and 4.4 ft. (1.3 m) wide at 30 ft. (9.2 m). |
|
| Choice of two optical modules depending |
|
| on ceiling height. For UL Listed |
|
| Requirements, the coverage is 360° by 54 ft. |
|
| (16.5 m) when mounted 10 to 13 ft. (3.1 m to |
|
| 4.0 m) using the |
|
| mounted from 15 to 18 ft. (4.6 m to 5.5 m) |
|
| using the |
• | Sensitivity: | Selectable for Standard, Intermediate or High. |
• | Tamper: | A tamper condition is signaled through the |
|
| Multiplex Bus and displays at the system |
|
| keypads. |
• Temperature: | The storage and operating temperature | |
|
| range is |
|
| For UL Listed Requirements, the |
|
| temperature range is +32°F to +120°F (0°C |
|
| to 49°C). |
• | Control Panel |
|
Requirements: DS7400, DS7400X, or DS7400Xi Control Panel with a DS7430 or DS7436 Multiplex Expansion Module. DS7400 and DS7400X require ROM version 1.07 or greater. The 9000 Series Control/Communicators with D8125MUX Module installed.
•Patents:This device is covered under one or more of the following U.S. patents: #4,764,755, #5,268,668, and #5,302,941.
| Address | Cover |
Mounting Base | Switches Top View of Enclosure Tamper |
with Cover Removed
The mounting surface should be solid and vibration free (i.e., drop tiles should be secured if the area above the
IMPORTANT tiles is used as an air return for HVAC systems).
•Select a location that is most likely to intercept an intruder moving across the coverage pattern. The recommended mounting height range is 8 to 18 ft. (2.4 to 5.5 m).
•Remove the cover by turning counterclockwise.
•Remove the base from the enclosure by pressing the two enclosure release tabs inward while lifting the enclosure away from the base.
Hint: Slightly rock the enclosure
•Route wiring as necessary to the rear of the base and through the center hole.
Be sure all wiring is unpowered
•Securely attach the base. Depending on local regulations, the base may be directly surface mounted using anchors, mollies or
NOTE: The MX938i base will not completely cover a