7.0Setup and Walk Testing

7.0Setup and Walk Testing

Before walk testing, the system should be fully wired, powered, and programmed.

IMPORTANT

Configure LED Configuration Switch (S1) to LED ON.

Replace the front cover.

NOTE: All testing must be performed with the front cover in place.

• Wait at least 2 minutes (with no motion in the coverage area) for the detector to setup.

• Walk test across the coverage pattern.

The edge of the coverage is determined by activation of the LED.

Walk test the unit from both directions to determine the boundaries.

On 2-wire systems, configure the LED to OFF when finished with walk tests.

8.0Maintenance

The range and coverage should be checked in accordance with the Walk Testing section (6.0) on a regular basis.

Consult the Control Panel’s User's Guide for the procedure on performing a zone test. Performing a zone test on a regular basis assures an alarm output prior to arming the system.

Excessive handling of the mirror surfaces may lead to performance degradation.

9.0Coverage Patterns

Refer to the mirror module and pattern drawings for masking information.

Before masking, be sure the chosen mirror surface is the correct one. When removing masking, remember, many adhesives will either destroy the mirror’s surface or leave residue behind to reduce coverage performance.

IMPORTANT

TOP VIEW

9 Meters

6

3

0

3

6

9

 

 

 

 

 

 

 

30

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR13-18 SIDE VIEW (Cross Section of 2 Opposite Zones)

 

 

 

 

 

 

 

 

 

9 Meters

6

3

0

3

6

9

20

 

 

 

 

 

20

15

 

 

 

 

 

4.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

3

10

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

0

 

 

 

 

 

 

 

30 Feet

20

10

0

10

20

30

0

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR8-13 SIDE VIEW (Cross Section of 2 Opposite Zones)

 

 

10

 

 

 

 

 

10

9 Meters

6

3

0

3

6

9

 

 

 

 

 

10

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

20

0

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 Feet

20

10

0

10

20

30

30

 

 

 

 

 

30

 

 

 

 

 

 

 

9 Meters

6

3

0

3

6

9

 

 

 

 

 

 

 

© 2004 Bosch Security Systems

03/04

130 Perinton Parkway, Fairport, New York, USA 14450-9199

MX938i Installation Instructions

Customer Service: (800) 289-0096; Technical Support: (888) 886-6189

P/N: 45988F Page 4

Page 4
Image 4
Bosch Appliances MX938I installation instructions 7.0Setup and Walk Testing, 8.0Maintenance, 9.0Coverage Patterns