Bosch Appliances NBN-733 installation manual 9.3Customer service

Models: NBN-733

1 44
Download 44 pages 5.22 Kb
Page 37
Image 37
9.3Customer service

DINION HD

 

Troubleshooting en 37

 

 

 

 

 

 

 

 

 

Malfunction

Possible causes

Solution

 

 

 

 

 

The unit is not

Power failure during

Have the unit checked by

 

operational after a

programming by firmware

Customer Service and

 

firmware upload.

file.

replace if necessary.

 

 

 

 

 

 

Incorrect firmware file.

Enter the IP address of

 

 

 

the unit followed by /

 

 

 

main.htm in your Web

 

 

 

browser and repeat the

 

 

 

upload.

 

 

 

 

 

Placeholder with a

JVM not installed on your

Install Sun JVM from the

 

red cross instead of

computer or not

product optical disk.

 

the ActiveX

activated.

 

 

components.

 

 

 

 

 

 

 

Web browser

Active proxy server in

Create a rule in the local

 

contains empty

network.

computer's proxy

 

fields.

 

settings to exclude local

 

 

 

IP addresses.

 

 

 

 

 

The POWER LED

Firmware upload failed.

Repeat firmware upload.

 

flashes red.

 

 

 

 

 

 

 

9.3Customer service

If a fault cannot be resolved, please contact your supplier or system integrator, or go directly to Bosch Security Systems Customer Service.

The version numbers of the internal firmware can be viewed on a special page. Please note this information before contacting Customer Service.

1.In the address bar of your browser, after the unit IP address, enter: /version

for example: 192.168.0.80/version

2.Write down the information or print out the page.

Bosch Security Systems

Installation Manual

AM18-Q0614 v1.0 2012.09

Page 37