Bosch Appliances NBN-733 Profile name, Target bit rate, Maximum bit rate, Encoding interval

Models: NDN-733 NBN-733

1 111
Download 111 pages 58.41 Kb
Page 55
Image 55

Camera Browser Interface

Encoder Settings en 61

 

 

9.1.3Profile name

If required, enter a new name for the profile.

9.1.4Target bit rate

To optimize use of the bandwidth in the network, limit the data rate for the camera. The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion.

For complex images or frequent changes of image content due to frequent movements, this limit can temporarily be exceeded up to the value entered in the Maximum bit rate field.

9.1.5Maximum bit rate

This maximum data rate is not exceeded under any circumstances. Depending on the video quality settings for the I-frames and P-frames, this can result in individual images being skipped.

The value entered here must be at least 10% higher than the value entered in the Target bit rate field. If the value entered here is too low, it is automatically adjusted.

9.1.6Encoding interval

The Encoding interval slider determines the interval at which images are encoded and transmitted. This can be particularly advantageous with low bandwidths. The image rate in ips (images per second) is displayed next to the slider.

9.1.7Standard definition video resolution

Select the desired resolution for the standard definition video image.

Note:

These resolutions are not used by a HD stream.

9.1.8Expert Settings

If necessary, use the expert settings to adapt the I-frame quality and the P-frame quality to specific requirements. The setting is based on the H.264 quantization parameter (QP).