! WARNING

BM 3609929656 10/03 10/17/03 12:13 PM Page 9

Maintenance

Service

Preventive maintenance

!WARNING performed by unauth- orized personnel may result in misplacing of internal wires and components which could cause serious hazard. We recommend that all tool service be performed by a Bosch Factory Service Center or Authorized Bosch Service Station.

TOOL LUBRICATION

Your Bosch tool has been properly lubricated and is ready to use. It is recommended that tools with gears be regreased with a special gear lubricant at every brush change.

CARBON BRUSHES

The brushes and commutator in your tool have been engineered for many hours of dependable service. To maintain peak efficiency of the motor, we recommend every two to six months the brushes be examined. Only genuine Bosch replacement brushes specially designed for your tool should be used.

BEARINGS

After about 300-400 hours of operation, or at every second brush change, the bearings

should be replaced at Bosch Factory Service Center or Authorized Bosch Service Station. Bearings which become noisy (due to heavy load or very abrasive material cutting) should be replaced at once to avoid overheating or motor failure.

Cleaning

To avoid accidents always disconnect the tool from the power supply before cleaning or

performing any maintenance. The tool may

be cleaned most effectively with compressed dry air. Always wear safety goggles when cleaning tools with compressed air.

Ventilation openings and switch levers must be kept clean and free of foreign matter. Do not attempt to clean by inserting pointed objects through openings.

Certain cleaning agents ! CAUTION and solvents damage plastic parts. Some of these are: gasoline,

carbon tetrachloride, chlorinated cleaning solvents, ammonia and household detergents that contain ammonia.

Accessories

!WARNING If an extension cord is necessary, a cord with

adequate size conductors that is capable of carrying the current necessary for your tool must be used. This will prevent

excessive voltage drop, loss of power or overheating. Grounded tools must use 3- wire extension cords that have 3-prong plugs and receptacles.

NOTE: The smaller the gauge number, the heavier the cord.

RECOMMENDED SIZES OF EXTENSION CORDS 120 VOLT ALTERNATING CURRENT TOOLS

Tool’s

Cord Size in A.W.G.

Wire Sizes in mm2

Ampere

 

 

 

 

 

 

 

 

Cord Length in Feet

Cord Length in Meters

Rating

25

50

100

150

15

30

60

120

 

3-6

 

 

 

 

 

 

 

 

18

16

16

14

0.75

0.75

1.5

2.5

6-8

18

16

14

12

0.75

1.0

2.5

4.0

8-10

18

16

14

12

0.75

1.0

2.5

4.0

10-12

16

16

14

12

1.0

2.5

4.0

12-16

14

12

 

 

 

 

 

 

 

 

 

1/4" Hex Universal Bit Holder and #2 phillips bit standard equipment on drywall drivers.

1/4" Hex Universal Bit Holder and 5/16" magnetic hex nut setter standard equipment on fastener drivers.

-9-

Page 9
Image 9
Bosch Power Tools 1405VSR, 1404VSRL, 1421VSR, 1423VSR, 1422VSRQ, 1420VSRL manual Maintenance, Accessories