BM 2610917139
Accessories
If an extension cord is necessary, a cord with adequate size conductors that is capable
of carrying the current necessary for your tool must be used. This will prevent excessive voltage drop, loss of power or overheating. Grounded tools must use 3- wire extension cords that have
NOTE: The smaller the gauge number, the heavier the cord.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Wire Sizes in mm2 | ||||||||
|
|
| Cord Size in A.W.G. | |||||||||
Tool’s | ||||||||||||
Ampere |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
|
| Cord Length in Feet | Cord Length in Meters | |||||||||
Rating |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| ||
|
| 25 | 50 | 100 | 150 | 15 | 30 | 60 | 120 |
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
18 | 16 | 16 | 14 | 0.75 | 0.75 | 1.5 | 2.5 |
| ||||
| 18 | 16 | 14 | 12 | 0.75 | 1.0 | 2.5 | 4.0 |
| |||
| 18 | 16 | 14 | 12 | 0.75 | 1.0 | 2.5 | 4.0 |
| |||
| 16 | 16 | 14 | 12 | 1.0 | 2.5 | 4.0 | — |
| |||
| 14 | 12 | — | — | — | — | — | — |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
* Standard parallel width guide fence | ** Vacuum hose |
** Deluxe angle fence | ** Chip bag |
** Rabbeting depth stop | (*= standard equipment) |
* Blade wrench 2.5mm | |
* Carbide reversible blades (2) | (**= optional accessories) |
| |
* Vacuum connector |
|