16 of 66
4.0 Hardware Installation

4.6 Installing accessories

Installer’s Note: Disconnect the FreeSpace 4400 system
from the AC (mains) power before making any input/output
connections.

4.6.1 Sensing microphones

Required accessory:

FreeSpace® 4400 System Auto Volume Mic Kit [PC042354 (U.S.),
PC042355 (Euro)]

Microphone installation:

The wall plate-microphone assembly can be installed using a
single-gang junction box, or the microphone can be removed
from the wall plate an d mounted directly on a flat surface.

Recommended wire length:

Up to 2000 ft (610 m) max., 24 AWG (0.2 mm2) shielded twisted
pair (shield tied to minus at FreeSpace 4400, floated at sense
mic).

Painting:

Before painting the wall
plate, install the sup-
plied tempor ary plug
over the microphone
opening. Remove the
plug when finished.

Mounting locations:

For mounting instructions, see “Mounting guidelines for sensing
microphones” on page 4.

4.6.2 Auto volume microphone inputs

Connect each sensing microphone to the SENSE MICRO-
PHONES jacks on the FreeSpace 4400 rear panel.

4.6.3 User interfaces

Required accessory: FreeSpace® 4400 System AVM 1-Zone
User Interface [PC042351] or
FreeSpace® 4400 System AVM 2-Zone
User Interface [PC042352] or
FreeSpace® 4400 System Page User
Interface [PC042353]

Required additional equipment (n ot sup plied) :

*FreeSpace® 4400 System AVM 2-Zo n e Us er In te rf ac e requires
the use of two (2) RJ45 connectors and two (2) Cat 5 cables.
Wall plate-microphone
assembly
(2) #6-32 (3 mm) screws
(2) Wire nuts
Paint plug
Junction box installation Surface-mounted mic
MUTE /
AUTO VOL
A
Wall plate
B
Keypad
C
RJ45
connector*
D
Cat 5 cable*
(with 4 twisted pairs)
E
Double-gang
junction box